Cited by 32

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

The effects of Porapak™ trap temperature on δ 18 O, δ 13 C, and Δ 47 values in preparing samples for clumped isotope analysis

Petersen, Sierra V., Winkelstern, Ian Z., Lohmann, Kyger C., Meyer, Kyle W.·2016·Rapid Communications in Mass Spectrometry

Abstract

Rationale: The clumped isotope paleothermometer, a new proxy widely applicable in studies of paleoclimate, tectonics, and paleontology, relates the abundance of doubly substituted isotopologues of carbonate‐derived CO 2 to the temperature of formation of the carbonate phase. As this technique becomes more widely used, more is discovered about the effects of everyday laboratory procedures on the clumped isotopic composition of CO 2 gas. Methods: Preparation of CO 2 for clumped isotope analysis requires the removal of isobaric contaminants prior to measurement, achieved dynamically by passing the CO 2 through a gas chromatography column using a helium carrier gas or cryogenically pumping CO 2 through a static trap filled with Porapak™ Q (PPQ) material. The stable and clumped isotopic compositions of carbonate standards prepared at PPQ trap temperatures between −40°C and −10°C were measured by isotope ratio mass spectrometry to evaluate potential artifacts introduced by the static PPQ trap method. Results: The stable isotopic composition of carbonates run at temperatures below −20°C was fractionated, despite achieving >99% retrieval of gas at temperatures as cold as −30°C. The δ 13 C and δ 18 O values decreased by ~0.01 and ~0.03 ‰/(°C below −20°C). The raw Δ 47 values decreased by 0.003–0.005 ‰/(°C below −20°C), but the final reference‐frame‐corrected values (Δ 47‐RFAC ) were unaffected as long as the carbonate samples and standard gases were prepared identically. Conclusions: Preparing carbonate samples for clumped isotope analysis using a PPQ trap that is too cold can result in erroneous stable isotopic compositions. New and existing labs using the static PPQ trap cleaning procedure should determine the ideal PPQ trap temperature for their particular system through monitoring not only yield through the PPQ trap, but also stable isotopic composition at various PPQ trap temperatures. Copyright © 2015 John Wiley & Sons, Ltd.

Overview

Integrity signals

Registry

Crossref · 10.1002/rcm.7438

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Research works printed but not linked: 15

  1. 10.1016/j.tecto.2015.02.019 · DOI · Paper page
  2. 10.1073/pnas.0902930106 · DOI
  3. 10.1016/j.gca.2011.09.025 · DOI · Paper page
  4. 10.1002/rcm.6436 · DOI
  5. 10.1029/2012JD017992 · DOI
  6. 10.1002/rcm.7022 · DOI
  7. 10.1073/pnas.1210930110 · DOI
  8. 10.1002/rcm.7175 · DOI
  9. 10.1073/pnas.1001824107 · DOI · Paper page
  10. 10.1016/j.gca.2011.08.044 · DOI
  11. 10.1002/rcm.6431 · DOI
  12. 10.1002/rcm.6634 · DOI
  13. 10.2110/jsr.2014.45 · DOI
  14. Atasoy D., 2015, Clumped isotope signals of biogenic and non‐ biogenic carbonates, Open Access Theses
  15. Clarke L. J., 2015, Marine bivalve mollusc shell Δ47‐temperature calibration using the MIRA mass spectrometer, Goldschmidt Conf. Abstr.

Cited by

See all 32

Metadata

Authors
Petersen, S. V., Winkelstern, I. Z., Lohmann, K. C., & Meyer, K. W.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2015-12-11
Volume
30
Issue
1
Pages
199-208
ISSN
  • 0951-4198
  • 1097-0231
Cited by
32
References
15
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of Porapak™ trap temperature on δ 18 O, δ 13 C, and Δ 47 values in preparing samples for clumped isotope analysis. https://app.cochat.ai/papers/10.1002/rcm.7438
The paper
Petersen, S. V., Winkelstern, I. Z., Lohmann, K. C., & Meyer, K. W. (2016). The effects of Porapak™ trap temperature on δ 18 O, δ 13 C, and Δ 47 values in preparing samples for clumped isotope analysis. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.7438