Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Triplex and quadruplex DNA structures studied by electrospray mass spectrometry

Open access
Rosu, Frédéric, Gabelica, Valérie, Houssier, Claude, Colson, Pierre, Pauw, Edwin De·2002·Rapid Communications in Mass Spectrometry

Abstract

DNA triplex and quadruplex structures have been successfully detected by electrospray ionization mass spectrometry (ESI‐MS). Circular dichroism and UV‐melting experiments show that these structures are stable in 150 mM ammonium acetate at pH 7 for the quadruplexes and pH 5.5 for the triplexes. The studied quadruplexes were the tetramer [d(TGGGGT)] 4 , the dimer [d(GGGGTTTTGGGG)] 2 , and the intramolecular folded strand dGGG(TTAGGG) 3 , which is an analog of the human telomeric sequence. The absence of sodium contamination allowed demonstration of the specific inclusion of n − 1 ammonium cations in the quadruplex structures, where n is the number of consecutive G‐tetrads. We also detected the complexes between the quadruplexes and the quadruplex‐specific drug mesoporphyrin IX. MS/MS spectra of [d(TGGGGT)] 4 and the complex with the drug are also reported. As the drug does not displace the ammonium cations, one can conclude that the drug binds at the exterior of the tetrads, and not between them. For the triplex structure the ESI‐MS spectra show the detection of the specific triplex, at m/z values typically higher than those typically observed for duplex species. Upon MS/MS the antigene strand, which is bound into the major groove of the duplex, separates from the triplex. This is the same dissociation pathway as in solution. To our knowledge this is the first report of a triplex DNA structure by electrospray mass spectrometry. Copyright © 2002 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.778

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
Rosu, F., Gabelica, V., Houssier, C., Colson, P., & Pauw, E. D.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2002-08
Volume
16
Issue
18
Pages
1729-1736
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2171231979
Cited by
160
References
1
FWCI
2.27
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Triplex and quadruplex DNA structures studied by electrospray mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.778
The paper
Rosu, F., Gabelica, V., Houssier, C., Colson, P., & Pauw, E. D. (2002). Triplex and quadruplex DNA structures studied by electrospray mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.778

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.