The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Computer-assisted navigation applied to fetal cardiac intervention
Abstract
BACKGROUND: Prenatal cardiac interventions (PCI) for human fetal aortic valve (AoV) stenosis can reduce left ventricular hypoplasia and restore ventricular growth and function. However, 'freehand' needle delivery from the maternal skin through the uterine wall, fetal chest and ventricular apex to cross the fetal AoV remains technically challenging and time intensive, and is the rate-limiting step in the procedure. METHODS: We developed a computer-assisted navigation (CANav) system that tracks the position and orientation of a two-dimensional (2D) ultrasound image relative to the trajectory of an electromagnetic (EM) embedded needle and stylet. We tested the CANav system in vitro using a water bath phantom, then in vivo using adult rats and pregnant (fetal) sheep. RESULTS: The CANav system accurately tracked the delivered needle position in both in vitro phantom and adult rat model experiments. We performed 22 PCI attempts with or without CANav in a fetal sheep model. Maternal laparotomy was required to adjust the fetal position in 50% of the procedures. The time required to deliver the needle from the skin into the left ventricle (LV) using CANav was 2.9 +/- 1.7 (range 2-7) min (n = 14) vs. 5.5 +/- 4.3 (range 1-12) min (n = 8) without CANav (p < 0.05). The time needed to cross the aortic valve once the needle was within the LV was similar with and without CANav (p = 0.19). CONCLUSIONS: CANav reduces the PCI time required to accurately deliver a needle to the fetal heart. Adaptations of this technical approach may be relevant to other congenital cardiac conditions and ultrasound-guided medical procedures.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Advantages in pre-operative risk stratification or intraoperative assistance are described in both subspecialties of OB/GYN.
“the advantages in pre-operative risk stratification or intraoperative assistance are described in both subspecialties of OB/GYN, e.g., in pre-operative endometrial cancer staging [209] and for fetoscopic surgical interventions [69,127].”
Citations
Cites
Hypoplastic left heart syndrome: Experience with palliative surgery
Norwood, W. I., Kirklin, J. K., & Sanders, S. P. (1980) · The American Journal of Cardiology · doi:10.1016/0002-9149(80)90224-6 · Cited by 424
Image Guided Navigation System to Measure Intraoperatively Acetabular Implant Alignment
DiGioia, A. M., Jaramaz, B., Blackwell, M., Simon, D. A., Morgan, F. G., Moody, J. E., Nikou, C., Colgan, B. D., Aston, C. A., LaBarca, R. S., et al. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810000-00003 · Cited by 408
Balloon Dilation of Severe Aortic Stenosis in the Fetus
Tworetzky, W., Wilkins-Haug, L. E., Jennings, R. W., van der Velde, M. E., Marshall, A. C., Marx, G. R., Colan, S. D., Benson, C. B., Lock, J. E., & Perry, S. B. (2004) · Circulation · doi:10.1161/01.cir.0000144357.29279.54 · Cited by 398
Fetal Aortic Valve Stenosis and the Evolution of Hypoplastic Left Heart Syndrome
Mäkikallio, K., McElhinney, D. B., Levine, J. C., Marx, G. R., Colan, S. D., Marshall, A. C., Lock, J. E., Marcus, E. N., & Tworetzky, W. (2006) · Circulation · doi:10.1161/circulationaha.105.588194 · Cited by 364
A review of calibration techniques for freehand 3-D ultrasound systems
Mercier, L., Langø, T., Lindseth, F., & Collins, D. L. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.11.015 · Cited by 326
Balloon dilatation of the aortic valve in the fetus: a report of two cases.
Maxwell, D. L., Ld, A., & Tynan, M. J. (1991) · Heart · doi:10.1136/hrt.65.5.256 · Cited by 251
Staged Reconstruction for Hypoplastic Left Heart Syndrome
Bove, E. L., & Lloyd, T. R. (1996) · Annals of Surgery · doi:10.1097/00000658-199609000-00015 · Cited by 239
Marshall, A. C., van der Velde, M. E., Tworetzky, W., Gomez, C. A., Wilkins-Haug, L. E., Benson, C. B., Jennings, R. W., & Lock, J. E. (2004) · Circulation · doi:10.1161/01.cir.0000135471.17922.17 · Cited by 239
Left Heart Obstructive Lesions and Left Ventricular Growth in the Midtrimester Fetus
Hornberger, L. K., Sanders, S. P., Rein, A. J. J. T., Spevak, P. J., Parness, I. A., & Colan, S. D. (1995) · Circulation · doi:10.1161/01.cir.92.6.1531 · Cited by 233
Wood, B. J., Zhang, H., Durrani, A. K., Glossop, N., Ranjan, S., Lindisch, D., Levy, E., Banovac, F., Borgert, J., Krueger, S., et al. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000148827.62296.b4 · Cited by 227
Fetal pulmonary valvuloplasty for critical pulmonary stenosis or atresia with intact septum
Tulzer, G., Arzt, W., Franklin, R. C. G., Loughna, P. V., Mair, R., & Gardiner, H. M. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11531-5 · Cited by 205
Accuracy assessment protocols for electromagnetic tracking systems
Frantz, D. D., Wiles, A. D., Leis, S., & Kirsch, S. R. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/314 · Cited by 173
Myocardial growth before and after birth: clinical implications *
Rudolph, A. M. (2000) · Acta paediatrica · doi:10.1111/j.1651-2227.2000.tb01201.x · Cited by 156
Wood, B. J., Locklin, J. K., Viswanathan, A., Kruecker, J., Haemmerich, D., Cebral, J., Sofer, A., Cheng, R., McCreedy, E. S., Cleary, K., et al. (2007) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2006.10.013 · Cited by 145
Myocardial growth before and after birth: clinical implications
Am, R. (2000) · Acta Paediatrica · doi:10.1080/080352500750028681 · Cited by 138
Aortic valvuloplasty in the fetus: Technical characteristics of successful balloon dilation
Marshall, A. C., Tworetzky, W., Bergersen, L. J., McElhinney, D. B., Benson, C. B., Jennings, R. W., Wilkins-Haug, L. E., Marx, G. R., & Lock, J. E. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2005.04.055 · Cited by 128
Tobita, K., & Keller, B. B. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.3.h959 · Cited by 108
Robotic surgery in urology: fact or fantasy?
Binder, J., Bräutigam, R., Jonas, D., & Bentas, W. (2004) · British Journal of Urology · doi:10.1046/j.1464-410x.2004.05130.x · Cited by 105
Performance of a miniature magnetic position sensor for three-dimensional ultrasound imaging
Leotta, D. F., Detmer, P. R., & Martin, R. W. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00043-4 · Cited by 105
Techniques for fast and accurate intrasurgical registration
Simon, D. A., Hebert, M., & Takeo Kanade, A. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:1 · Cited by 105
Evaluation of a miniature electromagnetic position tracker
Hummel, J. B., Figl, M., Kollmann, C., Bergmann, H., & Birkfellner, W. (2002) · Medical Physics · doi:10.1118/1.1508377 · Cited by 98
Prenatal Diagnosis of Severe Aortic Stenosis
McCaffrey, F. M., & Sherman, F. S. (1997) · Pediatric Cardiology · doi:10.1007/s002469900174 · Cited by 85
Fetoscopic surgery: Encouraged by clinical experience and boosted by instrument innovation
Deprest, J. A., Jani, J. C., Lewi, L., Ochsenbein‐Kölble, N., Cannie, M., Doné, E., Roubliova, X. I., Mieghem, T. V., Debeer, A., Debuck, F., et al. (2006) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2006.09.003 · Cited by 84
Factors affecting technical success of fetal aortic valve dilation
Wilkins-Haug, L. E., Tworetzky, W., Benson, C. B., Marshall, A. C., Jennings, R. W., & Lock, J. E. (2006) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.2732 · Cited by 73
Fetoscopic Direct Fetal Cardiac Access in Sheep
Kohl, T., Strümper, D., Witteler, R., Merschhoff, G., Aleksiene, R., Callenbeck, C., Asfour, B., Reckers, J., Aryee, S., Vahlhaus, C., et al. (2000) · Circulation · doi:10.1161/01.cir.102.14.1602 · Cited by 60
Barratt, D. C., Davies, A. H., Hughes, A. D., Thom, S., & Humphries, K. N. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00395-7 · Cited by 55
Computer-assisted orthopaedic surgery: minimally invasive hip and knee reconstruction
DiGioia, A. M., Blendea, S., & Jaramaz, B. (2004) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(03)00133-0 · Cited by 49
Augmented reality imaging technology for orthopaedic surgery
Nikou, C., DiGioia, A. M., Blackwell, M., Jaramaz, B., & Takeo Kanade, A. (2000) · Operative Techniques in Orthopaedics · doi:10.1016/s1048-6666(00)80047-6 · Cited by 46
Electromagnetic Tracking for Image-Guided Abdominal Procedures: Overall System and Technical Issues
Cleary, K., Zhang, H., Glossop, N., Levy, E. B., Wood, B. J., & Banovac, F. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616054 · Cited by 46
Rapid, easy and reliable calibration for freehand 3D ultrasound
Hsu, P.-W., Prager, R. W., Gee, A. H., & Treece, G. M. (2006) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.02.1427 · Cited by 42
Schwarz, E. R., Pollick, C., Meehan, W. P., & Kloner, R. A. (1998) · Basic Research in Cardiology · doi:10.1007/s003950050118 · Cited by 38
A needle tracking device for ultrasound guided percutaneous procedures
Chan, C., Lam, F., & Rohling, R. N. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.07.014 · Cited by 35
An Electronic Device for Needle Placement during Sonographically Guided Percutaneous Intervention
Howard, M. H., Nelson, R. C., Paulson, E. K., Kliewer, M. A., & Sheafor, D. H. (2001) · Radiology · doi:10.1148/radiology.218.3.r01mr10905 · Cited by 35
Deren, Ö., Özyüncü, Ö., Önderoğlu, L., & Durukan, T. (2007) · Fetal Diagnosis and Therapy · doi:10.1159/000098718 · Cited by 32
On the Development and Comparative Evaluation of an Ultrasound B-Mode Probe Calibration Method
Kowal, J., Amstutz, C. A., Caversaccio, M. D., & Nolte, L. P. (2003) · Computer Aided Surgery · doi:10.3109/10929080309146045 · Cited by 31
Combined stereotactic thalamotomy and posteroventral pallidotomy for Parkinson's disease
Iacono, R. P., Henderson, J. M., & Lonser, R. R. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:3 · Cited by 30
Chandra, V., Dutta, S., & Albanese, C. T. (2006) · Seminars in Pediatric Surgery · doi:10.1053/j.sempedsurg.2006.07.006 · Cited by 27
Function and Biomechanics of Developing Cardiovascular Systems
Keller, B. B. (2001) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-0207-3_13 · Cited by 15
Fetoscopic surgery: where are we today?
Kohl, T. (2004) · Current Opinion in Anaesthesiology · doi:10.1097/01.aco.0000137090.37484.88 · Cited by 10
Casula, R., Athanasiou, T., & Darzi, A. W. (2004) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.11 · Cited by 7
A simple calibration and evaluation phantom for ultrasound scanners
McCarty, K., & Stewart, W. R. (1982) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(82)80007-0 · Cited by 6
New form factors for sensors and field generators of a magnetic tracking system
Kirsch, S. R., Schilling, C., & Brunner, G. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.594019 · Cited by 4
Flagged first, then by citations
Research works printed but not linked: 1
- 10.1088/0031-9155/48/14/314 · DOI
Cited by
Sorted by citations
Current Status of Fetal Cardiac Intervention
McElhinney, D. B., Tworetzky, W., & Lock, J. E. (2010) · Circulation · doi:10.1161/circulationaha.109.870246 · Cited by 166
In‐plane ultrasonic needle tracking using a fiber‐optic hydrophone
Xia, W., Mari, J. M., West, S. J., Ginsberg, Y., David, A. L., Sebastien Ourselin, A., & Desjardins, A. E. (2015) · Medical Physics · doi:10.1118/1.4931418 · Cited by 58
Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44
“In case of the study of Emery et al., an AI-based navigation system for needle tracking in fetal aortic valvuloplasty promised increased safety, reduced intervention time, and transferability for other fetal interventions such as amniocentesis [69].”
BackgroundGrowth and hemodynamics after early embryonic aortic arch occlusion
Lindsey, S. E., Menon, P. G., Kowalski, W. J., Shekhar, A., Yalcin, H. C., Nishimura, N., Schaffer, C. B., Butcher, J. T., & Pekkan, K. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0633-1 · Cited by 42
Anesthesia for robotic cardiac surgery: An amalgam of technology and skill
Chauhan, S., & Sukesan, S. (2010) · Annals of Cardiac Anaesthesia · doi:10.4103/0971-9784.62947 · Cited by 34
Coded excitation ultrasonic needle tracking: An in vivo study
Xia, W., Ginsberg, Y., West, S. J., Nikitichev, D. I., Sebastien Ourselin, A., David, A. L., & Desjardins, A. E. (2016) · Medical Physics · doi:10.1118/1.4953205 · Cited by 26
In vitro hemodynamic investigation of the embryonic aortic arch at late gestation
Pekkan, K., Dasi, L. P., Nourparvar, P., Yerneni, S., Tobita, K., Fogel, M. A., Keller, B. B., & Yoganathan, A. P. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.03.013 · Cited by 23
The Learning Curve for a Fetal Cardiac Intervention Team
Emery, S. P., Kreutzer, J. N., McCaffrey, F. M., Sherman, F. S., Simhan, H. N., & Keller, B. B. (2010) · Minimally Invasive Surgery · doi:10.1155/2010/674185 · Cited by 15
Robotic-Assisted Cardiac Surgery
Leff, J., & Enriquez, L. J. (2012) · International Anesthesiology Clinics · doi:10.1097/aia.0b013e318250e44e · Cited by 11
MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images
Xu, F., Gao, D., Wang, S., & Zhanwen, A. (2018) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1004/1/012037 · Cited by 11
Fetal cardiac interventions: clinical and experimental research
Yuan, S., & Humuruola, G. (2016) · Advances in Interventional Cardiology · doi:10.5114/aic.2016.59359 · Cited by 10
Fetal cardiac intervention—Perspectives from a single center
Guseh, S. H., Friedman, K. G., & Wilkins-Haug, L. E. (2019) · Prenatal Diagnosis · doi:10.1002/pd.5631 · Cited by 8
Talcott, M., Akers, W. J., & Marini, R. P. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-409527-4.00025-0 · Cited by 4
BIOGRAPHY and CONTACT INFORMATION
Keller, B. B., Blvd, E. M. A., & Logsdon, M. (2012)
Current awareness in prenatal diagnosis
(2008) · Prenatal Diagnosis · doi:10.1002/pd.1857
Metadata
- Authors
- Emery, S. P., Kreutzer, J., Sherman, F. R., Fujimoto, K. L., Jaramaz, B., Nikou, C., Tobita, K., & Keller, B. B.
- Affiliations
- University of Pittsburgh (US)
- Western Pennsylvania Hospital (US)
- Corresponding author
- Keller, Bradley B.
- ORCID
- Venue
- The International Journal of Medical Robotics and Computer Assisted Surgery
- Publisher
- Wiley
- Published
- 2007-08-30
- Volume
- 3
- Issue
- 3
- Pages
- 187-198
- ISSN
- 1478-5951 (ISSN-L)
- 1478-596X
- OpenAlex
- W2005138614
- Cited by
- 15
- References
- 41
- Citations by year
- 2023: 1 · 2019: 1 · 2018: 1 · 2016: 2 · 2015: 2 · 2014: 1 · 2012: 2
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Medical Robotics and Computer Assisted Surgery (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R44HL076961, R43HL076961)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Keywords
- computer-assisted navigation, electromagnetic tracking, ultrasound-guided needle insertion, fetal sheep model, left ventricular hypoplasia, congenital heart disease
- MeSH terms
- Animals, Aortic Valve Stenosis, Equipment Design, Heart Defects, Congenital, Humans, Needles, Rats, Inbred Lew, Robotics, Cardiovascular Surgical Procedures, Ultrasonography, Prenatal, Ultrasonography, Interventional, Equipment Failure Analysis, Surgery, Computer-Assisted, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review