The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Summary of ISO/TC 201 Standard: VII ISO 15472 : 2001—surface chemical analysis—x‐ray photoelectron spectrometers—calibration of energy scales
Abstract
This international standard specifies a method for calibrating the binding energy scales of x‐ray photoelectron spectrometers, for general analytical purposes, using unmonochromated Al or Mg x‐rays or monochromated Al x‐rays. It is only applicable to instruments that have an ion gun for sputter cleaning. This international standard further specifies a method to establish a calibration schedule, to test for the binding energy scale linearity at one intermediate energy, to confirm the uncertainty of the scale calibration at one low and one high binding energy value, to correct for small drifts of that scale and to define the expanded uncertainty of the calibration of the binding energy scale for a confidence level of 95%. This uncertainty includes contributions for behaviour observed in inter‐laboratory studies but does not cover all of the defects that could occur. This international standard is not applicable to instruments with binding energy scale errors that are significantly non‐linear with energy, to instruments operated in the constant retardation ratio mode at retardation ratios of <10, to instruments with a spectrometer resolution worse than 1.5 eV or to instruments requiring tolerance limits of ±0.03 eV or less. This international standard does not provide a full calibration check, which would confirm the energy measured at each addressable point on the energy scale and would have to be performed in accordance with the manufacturer's recommended procedures. © Crown Copyright 2001. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
XPS: binding energy calibration of electron spectrometers 5?re-evaluation of the reference energies
Seah, M. P., Gilmore, I. S., & Beamson, G. (1998) · Surface and Interface Analysis · doi:10.1002/(sici)1096-9918(199808)26:9<642::aid-sia408>3.0.co;2-3 · Cited by 291
Self-citation
Cited by
X-ray photoelectron spectroscopy: Towards reliable binding energy referencing
Greczynski, G., & Hultman, L. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100591 · Cited by 2,528
Greczynski, G., & Hultman, L. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.04.226 · Cited by 1,426
Biesinger, M. C. (2022) · Applied Surface Science · doi:10.1016/j.apsusc.2022.153681 · Cited by 774
XPS and NEXAFS studies of aliphatic and aromatic amine species on functionalized surfaces
Graf, N., Yegen, E., Gross, T., Lippitz, A., Weigel, W., Krakert, S., Terfort, A., & Unger, W. E. S. (2009) · Surface Science · doi:10.1016/j.susc.2009.07.029 · Cited by 481
Filatova, E. O., & Konashuk, A. S. (2015) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.5b06843 · Cited by 449
Recommended Auger parameters for 42 elemental solids
Powell, C. J. (2012) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2011.12.001 · Cited by 424
Pinder, J. W., Major, G. H., Baer, D. R., Terry, J., Whitten, J. E., Čechal, J., Crossman, J. D., Lizarbe, A. J., Jafari, S., Easton, C. D., et al. (2024) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2023.100534 · Cited by 263
Fantauzzi, M., Pacella, A., Atzei, D., Gianfagna, A., Andreozzi, G. B., & Rossi, A. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3576-0 · Cited by 53
Metadata
- Authors
- Seah, M. P.
- Venue
- Surface and Interface Analysis
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 31
- Issue
- 8
- Pages
- 721-723
- ISSN
- 0142-2421 (ISSN-L)
- 1096-9918
- OpenAlex
- W2089984078
- Cited by
- 316
- References
- 1
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.