Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 290

The DOI matches its Crossref record.

Detection limits in XPS for more than 6000 binary systems using Al and Mg Kα X‐rays

Shard, Alexander G. · 2014 · Surface and Interface Analysis

Abstract

A simple approach to estimating the detection limits of X‐ray photoelectron spectroscopy (XPS) for any element in any elemental matrix is presented, using the intensity of the background at the expected position for the photoelectron peak to be detected. The approach has been extended to estimate the detection limit for all elements from lithium to bismuth in a similar range of elemental matrices. Using a number of assumptions, it is possible to obtain a reasonable estimate of the background intensity at any electron kinetic energy in the XPS spectrum of an element. Therefore, a detection limit for an arbitrary element homogeneously distributed in that matrix can be estimated. The results show that, although most elements are detectable at about the 1 at.% to 0.1 at.% level, for heavy elements in a light element matrix, the detection limit can be better than 0.01 at.%, whereas for light elements in a heavy element matrix, detection limits above 10 at.% are not uncommon. Two charts detailing the detection limits for all combinations of trace and matrix elements from lithium ( Z = 3) to bismuth ( Z = 83) are provided for Al Kα and Mg Kα X‐ray sources using a typical hemispherical analyser instrument which provides 10 6 counts eV for the Ag 3d 5/2 peak from pure silver. These detection limits can be scaled to estimate the detection limits for any given instrument and operating conditions if the intensity of the Ag 3d 5/2 peak from pure silver under those conditions is known. © 2014 Crown Copyright. Surface and Interface Analysis © 2014 John Wiley & Sons Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/sia.5406

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 290

Metadata

Authors
Shard, A. G.
Venue
Surface and Interface Analysis
Publisher
Wiley
Published
2014-02-03
Volume
46
Issue
3
Pages
175-185
ISSN
  • 0142-2421 (ISSN-L)
  • 1096-9918
OpenAlex
W1918923214
Cited by
290
References
0
FWCI
4.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection limits in XPS for more than 6000 binary systems using Al and Mg Kα X‐rays. https://app.cochat.ai/papers/10.1002/sia.5406
The paper
Shard, A. G. (2014). Detection limits in XPS for more than 6000 binary systems using Al and Mg Kα X‐rays. Surface and Interface Analysis. https://doi.org/10.1002/sia.5406

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.