Spectrum bias: a quantitative and graphical analysis of the variability of medical diagnostic test performance
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A Correction to this article has been published in Statistics in Medicine 2005, 24:(11) 1782. The performance of a medical diagnostic test may vary in a subgroup of patients according to the severity and clinical presentation of the disease. This phenomenon is often referred to as the spectrum effect. There is currently no technique to determine in which situations this spectrum effect may lead to a spectrum bias, that is, a distortion of the posterior probability which can potentially affect the clinical decision. We show that spectrum bias, on either a positive or a negative test result, can be expressed as the subgroup‐specific likelihood ratio (LR) divided by the LR in the overall population of patients. This assessment of spectrum bias is independent of the pretest probability. We present here the test statistic and its variance and also propose a mode of graphically visualizing the presence of spectrum bias. We applied it to 15 examples from the literature, of which three are discussed in detail. In two examples, there was spectrum bias: (1) diagnosis of urinary tract infection in subgroups of low or high risk patients when using the dipstick test, and (2) diagnosis of left ventricular hypertrophy using electrocardiography in subjects with different body mass index. In a third example, there was no spectrum bias for the diagnosis of coronary heart disease in subgroups of patients defined by age, sex or comorbidities when using exercise electrocardiography. As sensitivity and specificity usually vary in opposite directions from one subgroup to the other, the ratio of LRs tends to remain constant, resulting in no or little spectrum bias. We conclude that spectrum effect is more common than spectrum bias and that clinical decisions are affected only under certain conditions. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189 · cited 1×
“[6] showed changes in sensitivity, speci city and likelihood ratio of the exercise electrocardiography for coronary heart disease (against the gold standard of coronary angiography) among subgroups of patients de ned by age, sex, comorbidities and a series of other factors.”
Cited by
Cohen, J. F., Chalumeau, M., Cohen, R., Korevaar, D. A., Khoshnood, B., & Bossuyt, P. M. M. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2014.09.005 · Cited by 413
Cepoiu, M., McCusker, J., Cole, M. G., Sewitch, M., Belzile, E., & Ciampi, A. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0428-5 · Cited by 392
Enhanced liver fibrosis test can predict clinical outcomes in patients with chronic liver disease
Parkes, J., Roderick, P., Harris, S., Day, C., Mutimer, D., Collier, J., Lombard, M., Alexander, G., Ramage, J., Dusheiko, G., et al. (2010) · Gut · doi:10.1136/gut.2009.203166 · Cited by 351
Conybeare, D., Behar, E., Solomon, A., Newman, M. G., & Borkovec, T. D. (2012) · Journal of Clinical Psychology · doi:10.1002/jclp.21845 · Cited by 317
“59), possibly due to overlap between measures—overlap that may be attenuated in a clinical sample, given the greater ease with which different types of symptoms can be discriminated from one another among samples with a broader range of symptom severity (Goehring et al., 2004).”
BackgroundJonas, D. E., Amick, H. R., Feltner, C., Weber, R. P., Arvanitis, M., Stine, A., Lux, L., & Harris, R. P. (2017) · JAMA · doi:10.1001/jama.2016.19635 · Cited by 267
Shiha, G., Ibrahim, A., Helmy, A., Sarin, S. K., Omata, M., Kumar, A., Bernstien, D., Maruyama, H., Saraswat, V., Chawla, Y., et al. (2017) · Hepatology International · doi:10.1007/s12072-016-9760-3 · Cited by 238
“In addition, performance of diagnostic tests may vary according to the severity and clinical presentation of the disease, called spectrum bias [7].”
BackgroundThe US Food and Drug Administration perspective on cancer biomarker development
Gutman, S., & Kessler, L. G. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1911 · Cited by 176
“The complexity of identifying the correct study endpoints to properly address spectrum bia”
BackgroundDecision-analytic modeling to evaluate benefits and harms of medical tests: uses and limitations
Trikalinos, T. A., Siebert, U., & Lau, J. (2009) · Medical Decision Making · doi:10.1177/0272989x09345022 · Cited by 88
“, differences in the calculated sensitivity and specificity of a medical test as the case-mix of the studied population shifts).(46;47) Indeed, empirical studies have frequently revealed substantial variation of test performance metrics in studies with different disease prevelence.”
BackgroundKline, G., Buse, J., & Krause, R. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.02.008 · Cited by 62
Romme, J. J. C. M., van Dijk, N., Boer, K. R., Bossuyt, P. M. M., Wieling, W., & Reitsma, J. B. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp314 · Cited by 55
Metadata
- Authors
- Goehring, C., Perrier, A., & Morabia, A.
- Venue
- Statistics in Medicine
- Publisher
- Wiley
- Published
- 2003-10-29
- Volume
- 23
- Issue
- 1
- Pages
- 125-135
- ISSN
- 0277-6715 (ISSN-L)
- 1097-0258
- OpenAlex
- W2053090072
- Cited by
- 90
- References
- 1
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.