The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Aqueous‐Phase Synthesis of Highly Luminescent CdTe/ZnTe Core/Shell Quantum Dots Optimized for Targeted Bioimaging
Abstract
Semiconductor quantum dots (QDs) have traditionally been synthesized in organic phase and transferred to aqueous solution by functionalizing their surface with silica, polymers, short‐chain thiol ligand, or phospholipid micelles. However, these complex steps result in i) a reduction of the quantum yield (QY) of QDs, ii) partial degrdation of the QDs, and iii) a drastic increase in the hydrodynamic size of QDs, which may hinder their biomedical applications. In this work, the fabrication and applications of cysteine‐capped CdTe/ZnTe QDs, which are directly synthesized in aqueous media, as optical probes for specific targeting of pancreatic and esophageal cancer cells in vitro are reported, as well as their capability for in vivo imaging. The CdTe/ZnTe QDs are synthesized in a one‐pot method and capped with amino acid cysteine, which contains both carboxyl and amine functional groups on their surfaces for bioconjugation. The fabricated QDs have an ultrasmall hydrodynamic diameter (3–5 nm), possess high QY (52%), and are non‐toxic to cells at experimental dosages. Confocal imaging is used to demonstrate a receptor‐mediated uptake of antibody‐conjugated QDs into pancreatic cancer cells in vitro. In vitro cytotoxicity studies (MTS‐assay) show that the IC 50 value of these QDs is ≈160 µg mL−1, demonstrating low toxicity. In addition, the QDs are used for small‐animal imaging where the in vivo biocompatiblity of these QDs and their clearance following systemic injection is studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Dabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
Cited by
Ghosh Chaudhuri, R., & Paria, S. (2012) · Chemical Reviews · doi:10.1021/cr100449n · Cited by 3,614
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Self-citationDesigning multifunctional quantum dots for bioimaging, detection, and drug delivery
Zrazhevskiy, P., Sena, M., & Gao, X. (2010) · Chemical Society Reviews · doi:10.1039/b915139g · Cited by 997
Quantum dots: bright and versatile in vitro and in vivo fluorescence imaging biosensors
Wegner, K. D., & Hildebrandt, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00532e · Cited by 984
Hildebrandt, N., Spillmann, C. M., Algar, W. R., Pons, T., Stewart, M. H., Oh, E., Susumu, K., Díaz, S. A., Delehanty, J. B., & Medintz, I. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00030 · Cited by 730
Metadata
- Authors
- Law, W., Yong, K., Roy, I., Ding, H., Hu, R., Zhao, W., & Prasad, P. N.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2009-06-02
- Volume
- 5
- Issue
- 11
- Pages
- 1302-1310
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2118320933
- Cited by
- 185
- References
- 2
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.