Cell Docking in Double Grooves in a Microfluidic Channel
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Microstructures that generate shear‐protected regions in microchannels can rapidly immobilize cells for cell‐based biosensing and drug screening. Here, a two‐step fabrication method is used to generate double microgrooves with various depth ratios to achieve controlled double‐level cell patterning while still providing shear protection. Six microgroove geometries are fabricated with different groove widths and depth ratios. Two modes of cell docking are observed: cells docked upstream in sufficiently deep and narrow grooves, and downstream in shallow, wide grooves. Computational flow simulations link the groove geometry and bottom shear stress to the experimental cell docking patterns. Analysis of the experimental cell retention in the double grooves demonstrates its linear dependence on inlet flow speed, with slope inversely proportional to the sheltering provided by the groove geometry. Thus, double‐grooved microstructures in microfluidic channels provide shear‐protected regions for cell docking and immobilization and appear promising for cell‐based biosensing and drug discovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chung, T. J. (2002) · Cambridge University Press eBooks · doi:10.1017/cbo9780511606205 · Cited by 505
Cited by
Rapid prototyping polymers for microfluidic devices and high pressure injections
Sollier, E., Murray, C., Maoddi, P., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20514e · Cited by 407
High-throughput size-based rare cell enrichment using microscale vortices
Hur, S. C., Mach, A. J., & Di Carlo, D. (2011) · Biomicrofluidics · doi:10.1063/1.3576780 · Cited by 317
Biofabrication of a three-dimensional liver micro-organ as an in vitro drug metabolism model
Chang, R., Emami, K., Wu, H., & Sun, W. (2010) · Biofabrication · doi:10.1088/1758-5082/2/4/045004 · Cited by 247
“…cellular microenvironment and enable parallelization of cell-based assays, (2) tunable hydrogels to create three-dimensional microenvironments and (3) bioreactors to control nutrient transport and fluid shear stresses (Khetani and Bhatia 2006, Wong et al 2008, Wu et al 2008, Khabiry et al 2009).”
BackgroundMicrofluidics for Manipulating Cells
Mu, X., Zheng, W., Sun, J., Zhang, W., & Jiang, X. (2013) · Small · doi:10.1002/smll.201200996 · Cited by 214
Micro-dissected tumor tissues on chip: an ex vivo method for drug testing and personalized therapy
Astolfi, M., Péant, B., Lateef, M. A., Rousset, N., Kendall-Dupont, J., Carmona, E., Monet, F., Saad, F., Provencher, D., Mes-Masson, A.-M., et al. (2016) · Lab on a Chip · doi:10.1039/c5lc01108f · Cited by 182
Patra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C. (2013) · Biomicrofluidics · doi:10.1063/1.4824480 · Cited by 109
Microfluidic Systems for Neural Cell Studies
Babaliari, E., Ranella, A., & Stratakis, E. (2023) · Bioengineering · doi:10.3390/bioengineering10080902 · Cited by 13
Metadata
- Authors
- Khabiry, M., Chung, B. G., Hancock, M. J., Soundararajan, H. C., Du, Y., Cropek, D., Lee, W. G., & Khademhosseini, A.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2009-05-07
- Volume
- 5
- Issue
- 10
- Pages
- 1186-1194
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W1971974179
- Cited by
- 53
- References
- 1
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.