The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.
A microfluidic device for uniform-sized cell spheroids formation, culture, harvesting and flow cytometry analysis
Open accessAbstract
Culture of cells as three-dimensional (3D) aggregates, named spheroids, possesses great potential to improve in vitro cell models for basic biomedical research. However, such cell spheroid models are often complicated, cumbersome, and expensive compared to conventional Petri-dish cell cultures. In this work, we developed a simple microfluidic device for cell spheroid formation, culture, and harvesting. Using this device, cells could form uniformly sized spheroids due to strong cell–cell interactions and the spatial confinement of microfluidic culture chambers. We demonstrated cell spheroid formation and culture in the designed devices using embryonic stem cells, carcinoma cells, and fibroblasts. We further scaled up the device capable of simultaneously forming and culturing 5000 spheroids in a single chip. Finally, we demonstrated harvesting of the cultured spheroids from the device with a simple setup. The harvested spheroids possess great integrity, and the cells can be exploited for further flow cytometry assays due to the ample cell numbers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While intravital imaging has proven extremely useful in the study of metastasis[6–7], it requires specialized expertise and equipment, and high image resolution is harder to attain in some visceral organs due to the depth of their location.”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [6]
In the citing paper
“For example, retrieving cells from microfluidic devices for subsequent biochemical studies is possible but not straightforward [6].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [6]
In the citing paper
“A number of groups were able to generate spheroids in chip-based devices171–173, but the spheroids lack spatial complexity and cell types compared to fully-developed organoids.”
From Towards organoid culture without Matrigel (2021) · cites this paper as [171]
Citations
Cites
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Cell and environment interactions in tumor microregions: the multicell spheroid model.
Sutherland, R. M. (1988) · Science · doi:10.1126/science.2451290 · Cited by 1,803
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Self-citationBartosh, T. J., Ylöstalo, J. H., Mohammadipoor, A., Bazhanov, N., Coble, K., Claypool, K., Lee, R. H., Choi, H., & Prockop, D. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1008117107 · Cited by 958
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
Experimental anti-tumor therapy in 3-D: Spheroids – old hat or new challenge?
Friedrich, J., Ebner, R., & Kunz-Schughart, L. A. (2007) · International Journal of Radiation Biology · doi:10.1080/09553000701727531 · Cited by 446
Fabrication of microfluidic devices using polydimethylsiloxane
Friend, J., & Yeo, L. (2010) · Biomicrofluidics · doi:10.1063/1.3259624 · Cited by 425
Research works printed but not linked: 2
- 2007, Biochip. J., 1, 17
- 2008, Introduction to Particle Technology
Cited by
Towards organoid culture without Matrigel
Kozlowski, M. T., Crook, C. J., & Ku, H. T. (2021) · Communications Biology · doi:10.1038/s42003-021-02910-8 · Cited by 409
Hydrogel microenvironments for cancer spheroid growth and drug screening
Li, Y., & Kumacheva, E. (2018) · Science Advances · doi:10.1126/sciadv.aas8998 · Cited by 351
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Engineering Multi‐Cellular Spheroids for Tissue Engineering and Regenerative Medicine
Kim, S., Kim, E. M., Yamamoto, M., Park, H., & Shin, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000608 · Cited by 234
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
Metadata
- Authors
- Patra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C.
- Affiliations
- National Yang Ming University (TW)
- Research Center for Applied Sciences, Academia Sinica 3 , Taipei 11529, Taiwan
- Research Center for Applied Science, Academia Sinica (TW)
- National Taiwan University (TW)
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2013-09-01
- Volume
- 7
- Issue
- 5
- Pages
- 54114-54114
- ISSN
- 1932-1058 (ISSN-L)
- PMC
- PMC3808411
- OpenAlex
- W1988781086
- Cited by
- 109
- References
- 38
- Citations by year
- 2025: 6 · 2024: 6 · 2023: 8 · 2022: 7 · 2021: 11 · 2020: 16 · 2019: 6 · 2018: 13 · 2017: 13 · 2016: 6 · 2015: 8 · 2014: 7 · 2013: 1
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Biomicrofluidics (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council (101-2628-E-001-002-MY3)
- Academia Sinica
- National Health Research Institutes
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- cell spheroids, microfluidics, 3D cell culture, spheroid formation, flow cytometry, embryonic stem cells, carcinoma cells, fibroblasts, cell-cell interactions, spatial confinement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfluidic device for uniform-sized cell spheroids formation, culture, harvesting and flow cytometry analysis. https://app.cochat.ai/papers/10.1063/1.4824480
- The paper
- Patra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C. (2013). A microfluidic device for uniform-sized cell spheroids formation, culture, harvesting and flow cytometry analysis. Biomicrofluidics. https://doi.org/10.1063/1.4824480
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.