The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Sniffing the Unique “Odor Print” of Non‐Small‐Cell Lung Cancer with Gold Nanoparticles
Open accessAbstract
A highly sensitive and fast‐response array of sensors based on gold nanoparticles, in combination with pattern recognition methods, can distinguish between the odor prints of non‐small‐cell lung cancer and negative controls with 100% accuracy, with no need for preconcentration techniques. Additionally, preliminary results indicate that the same array of sensors might serve as a better tool for understanding the biochemical source of volatile organic compounds that might occur in cancer cells and appear in the exhaled breath, as compared to traditional spectrometry techniques. The reported results provide a launching pad to initiate a bedside tool that might be able to screen for early stages of lung cancer and allow higher cure rates. In addition, such a tool might be used for the immediate diagnosis of fresh (frozen) tissues of lung cancer in operating rooms, where a dichotomic diagnosis is crucial to guide surgeons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldstraw, P., Crowley, J., Chansky, K., Giroux, D. J., Groome, P. A., Rami-Porta, R., Postmus, P. E., Rusch, V., & Sobin, L. (2007) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e31812f3c1a · Cited by 3,655
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Persistent oxidative stress in cancer
Toyokuni, S., Okamoto, K., Yodoi, J., & Hiai, H. (1995) · FEBS Letters · doi:10.1016/0014-5793(94)01368-b · Cited by 1,219
Cited by
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Self-citationGold nanoparticle-enabled biological and chemical detection and analysis
Jans, H., & Huo, Q. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15280g · Cited by 725
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationFlexible Sensors Based on Nanoparticles
Segev-Bar, M., & Haick, H. (2013) · ACS Nano · doi:10.1021/nn402728g · Cited by 511
Self-citationQiao, X., Su, B., Liu, C., Song, Q., Luo, D., Mo, G., & Wang, T. (2018) · Advanced Materials · doi:10.1002/adma.201702275 · Cited by 469
Metadata
- Authors
- Barash, O., Peled, N., Hirsch, F. R., & Haick, H.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2009-11-11
- Volume
- 5
- Issue
- 22
- Pages
- 2618-2624
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2029176665
- Cited by
- 183
- References
- 3
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sniffing the Unique “Odor Print” of Non‐Small‐Cell Lung Cancer with Gold Nanoparticles. https://app.cochat.ai/papers/10.1002/smll.200900937
- The paper
- Barash, O., Peled, N., Hirsch, F. R., & Haick, H. (2009). Sniffing the Unique “Odor Print” of Non‐Small‐Cell Lung Cancer with Gold Nanoparticles. Small. https://doi.org/10.1002/smll.200900937
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.