The DOI matches its Crossref record.
Tumor Targeting and Imaging Using Cyclic RGD‐PEGylated Gold Nanoparticle Probes with Directly Conjugated Iodine‐125
Abstract
Radioactive iodine‐labeled, cyclic RGD‐PEGylated gold nanoparticle (AuNP) probes are designed and synthesized for targeting cancer cells and imaging tumor sites. These iodine‐125‐labeled cRGD–PEG–AuNP probes are stable in various conditions including a range of pHs and high salt and temperature conditions. These probes can target selectively and be taken up by tumor cells via integrin α v β 3‐receptor‐mediated endocytosis with no cytotoxicity. The probes show a significant increase in the avidity of α v β 3 integrin compared to the corresponding free cRGD peptides. In‐vivo SPECT/CT imaging results show that the iodine‐125‐labeled cRGD–PEG–AuNP probes can target the tumor site as soon as 10 min after injection, and also that cyclic RGD peptides are needed for efficient and long‐term in‐vivo monitoring. The results suggest that the probes circulate through the whole body, including renal filtration, and are excretable. These promising results show that radioactive‐iodine‐labeled gold nanoprobes have potential for highly specific and sensitive tumor imaging or for use as angiogenesis‐targeted SPECT/CT imaging probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sapsford, K. E., Algar, W. R., Berti, L., Gemmill, K. B., Casey, B. J., Oh, E., Stewart, M. H., & Medintz, I. L. (2013) · Chemical Reviews · doi:10.1021/cr300143v · Cited by 1,423
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Applications of nanoparticles for diagnosis and therapy of cancer
Baetke, S. C., Lammers, T., & Kiessling, F. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20150207 · Cited by 494
A Plasmonic Gold Nanostar Theranostic Probe for In Vivo Tumor Imaging and Photothermal Therapy
Liu, Y., Ashton, J. R., Moding, E. J., Yuan, H., Register, J. K., Fales, A. M., Choi, J., Whitley, M. J., Zhao, X., Qi, Y., et al. (2015) · Theranostics · doi:10.7150/thno.11974 · Cited by 308
Nanobody: The “Magic Bullet” for Molecular Imaging?
Chakravarty, R., Goel, S., & Cai, W. (2014) · Theranostics · doi:10.7150/thno.8006 · Cited by 288
Metadata
- Authors
- Kim, Y., Jeon, J., Hong, S. H., Rhim, W., Lee, Y., Youn, H., Chung, J., Lee, M. C., Lee, D. S., Kang, K. W., & Nam, J.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2011-06-20
- Volume
- 7
- Issue
- 14
- Pages
- 2052-2060
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2136418036
- Cited by
- 189
- References
- 0
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tumor Targeting and Imaging Using Cyclic RGD‐PEGylated Gold Nanoparticle Probes with Directly Conjugated Iodine‐125. https://app.cochat.ai/papers/10.1002/smll.201100927
- The paper
- Kim, Y., Jeon, J., Hong, S. H., Rhim, W., Lee, Y., Youn, H., Chung, J., Lee, M. C., Lee, D. S., Kang, K. W., & Nam, J. (2011). Tumor Targeting and Imaging Using Cyclic RGD‐PEGylated Gold Nanoparticle Probes with Directly Conjugated Iodine‐125. Small. https://doi.org/10.1002/smll.201100927
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.