The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Chemical Imaging Beyond the Diffraction Limit: Experimental Validation of the PTIR Technique
Abstract
Photothermal induced resonance (PTIR) has recently attracted great interest for enabling chemical identification and imaging with nanoscale resolution. In this work, electron beam nanopatterned polymer samples are fabricated directly on 3D zinc selenide prisms and used to experimentally evaluate the PTIR lateral resolution, sensitivity and linearity. It is shown that PTIR lateral resolution for chemical imaging is comparable to the lateral resolution obtained in the atomic force microscopy height images, up to the smallest feature measured (100 nm). Spectra and chemical maps are produced from the thinnest sample analyzed (40 nm). More importantly, experiments show for the first time that the PTIR signal increases linearly with thickness for samples up to ≈ 1 μm (linearity limit); a necessary requirement towards the use of the PTIR technique for quantitative chemical analysis at the nanoscale. Finally, the analysis of thicker samples provides the first evidence that the previously developed PTIR signal generation theory is correct. It is believed that the findings of this work will foster nanotechnology development in disparate applications by proving the basis for quantitative chemical analysis with nanoscale resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effective Path Length in Attenuated Total Reflection Spectroscopy
Averett, L. A., Griffiths, P. R., & Nishikida, K. (2008) · Analytical Chemistry · doi:10.1021/ac7025892 · Cited by 133
Cited by
AFM-IR: Technology and Applications in Nanoscale Infrared Spectroscopy and Chemical Imaging
Dazzi, A., & Prater, C. B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00448 · Cited by 1,082
Infrared and Raman chemical imaging and spectroscopy at the nanoscale
Kurouski, D., Dazzi, A., Zenobi, R., & Centrone, A. (2020) · Chemical Society Reviews · doi:10.1039/c8cs00916c · Cited by 324
Self-citationNanoscale chemical imaging by photoinduced force microscopy
Nowak, D., Morrison, W., Wickramasinghe, H. K., Jahng, J., Potma, E., Wan, L., Ruiz, R., Albrecht, T. R., Schmidt, K., Frommer, J., et al. (2016) · Science Advances · doi:10.1126/sciadv.1501571 · Cited by 329
Infrared Imaging and Spectroscopy Beyond the Diffraction Limit
Centrone, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040435 · Cited by 295
Self-citationRuggeri, F. S., Longo, G., Faggiano, S., Lipiec, E., Pastore, A., & Dietler, G. (2015) · Nature Communications · doi:10.1038/ncomms8831 · Cited by 289
Metadata
- Authors
- Lahiri, B., Holland, G., & Centrone, A.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2012-10-04
- Volume
- 9
- Issue
- 3
- Pages
- 439-445
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2151198402
- Cited by
- 175
- References
- 1
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemical Imaging Beyond the Diffraction Limit: Experimental Validation of the PTIR Technique. https://app.cochat.ai/papers/10.1002/smll.201200788
- The paper
- Lahiri, B., Holland, G., & Centrone, A. (2013). Chemical Imaging Beyond the Diffraction Limit: Experimental Validation of the PTIR Technique. Small. https://doi.org/10.1002/smll.201200788
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.