The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Nanoscale chemical imaging by photoinduced force microscopy
Open accessAbstract
Photoinduced force microscopy resolves nanometer-scale topology with chemical recognition based on material absorption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novotny, L., & Hecht, B. (2025) · Cambridge University Press eBooks · doi:10.1017/9781108781503 · Cited by 6,220
Block Copolymer Thermodynamics: Theory and Experiment
Bates, F. S., & Fredrickson, G. H. (1990) · Annual Review of Physical Chemistry · doi:10.1146/annurev.pc.41.100190.002521 · Cited by 3,960
Optical stethoscopy: Image recording with resolution λ/20
Pohl, D. W., Denk, W., & Lanz, M. (1984) · Applied Physics Letters · doi:10.1063/1.94865 · Cited by 2,040
Block Copolymer Lithography: Periodic Arrays of ~10 11 Holes in 1 Square Centimeter
Park, M., Harrison, C., Chaikin, P. M., Register, R. A., & Adamson, D. H. (1997) · Science · doi:10.1126/science.276.5317.1401 · Cited by 1,866
Epitaxial self-assembly of block copolymers on lithographically defined nanopatterned substrates
Ouk Kim, S., Solak, H. H., Stoykovich, M. P., Ferrier, N. J., de Pablo, J. J., & Nealey, P. F. (2003) · Nature · doi:10.1038/nature01775 · Cited by 1,660
Nanoscale chemical analysis by tip-enhanced Raman spectroscopy
Stöckle, R. M., Suh, Y. D., Deckert, V., & Zenobi, R. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)01451-7 · Cited by 1,606
(1988) · Springer eBooks · doi:10.1007/978-94-009-2875-6 · Cited by 1,569
Breaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale
Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S., & Kostelak, R. L. (1991) · Science · doi:10.1126/science.251.5000.1468 · Cited by 1,534
Applications of photoacoustic sensing techniques
Tam, A. C. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.381 · Cited by 1,306
Density Multiplication and Improved Lithography by Directed Block Copolymer Assembly
Ruiz, R., Kang, H., Detcheverry, F. A., Dobisz, E., Kercher, D. S., Albrecht, T. R., de Pablo, J. J., & Nealey, P. F. (2008) · Science · doi:10.1126/science.1157626 · Cited by 1,150
Self-citation
Cited by
Controlling Molecular Doping in Organic Semiconductors
Jacobs, I. E., & Moulé, A. J. (2017) · Advanced Materials · doi:10.1002/adma.201703063 · Cited by 572
Photoinduced Force Microscopy as an Efficient Method Towards the Detection of Nanoplastics
C. ten Have, I., Duijndam, A. J. A., Oord, R., van Berlo‐van den Broek, H. J. M., Vollmer, I., Weckhuysen, B. M., & Meirer, F. (2021) · Chemistry–Methods · doi:10.1002/cmtd.202100017 · Cited by 34
Metadata
- Authors
- Nowak, D., Morrison, W., Wickramasinghe, H. K., Jahng, J., Potma, E., Wan, L., Ruiz, R., Albrecht, T. R., Schmidt, K., Frommer, J., Sanders, D. P., & Park, S.
- Venue
- Science Advances
- Published
- 2016-03-04
- Volume
- 2
- Issue
- 3
- Pages
- e1501571-e1501571
- ISSN
- 2375-2548 (ISSN-L)
- OpenAlex
- W2308344008
- Cited by
- 329
- References
- 34
- FWCI
- 14.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoscale chemical imaging by photoinduced force microscopy. https://app.cochat.ai/papers/10.1126/sciadv.1501571
- The paper
- Nowak, D., Morrison, W., Wickramasinghe, H. K., Jahng, J., Potma, E., Wan, L., Ruiz, R., Albrecht, T. R., Schmidt, K., Frommer, J., Sanders, D. P., & Park, S. (2016). Nanoscale chemical imaging by photoinduced force microscopy. Science Advances. https://doi.org/10.1126/sciadv.1501571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.