The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
High-Responsivity Graphene/InAs Nanowire Heterojunction Near-Infrared Photodetectors with Distinct Photocurrent On/Off Ratios
Abstract
Graphene is a promising candidate material for high-speed and ultra-broadband photodetectors. However, graphene-based photodetectors suffer from low photoreponsivity and I(light)/I(dark) ratios due to their negligible-gap nature and small optical absorption. Here, a new type of graphene/InAs nanowire (NW) vertically stacked heterojunction infrared photodetector is reported, with a large photoresponsivity of 0.5 AW(-1) and I(light)/I(dark) ratio of 5 × 10(2), while the photoresponsivity and I(light)/I(dark) ratio of graphene infrared photodetectors are 0.1 mAW(-1) and 1, respectively. The Fermi level (E(F)) of graphene can be widely tuned by the gate voltage owing to its 2D nature. As a result, the back-gated bias can modulate the Schottky barrier (SB) height at the interface between graphene and InAs NWs. Simulations further demonstrate the rectification behavior of graphene/InAs NW heterojunctions and the tunable SB controls charge transport across the vertically stacked heterostructure. The results address key challenges for graphene-based infrared detectors, and are promising for the development of graphene electronic and optoelectronic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Graphene photodetectors for high-speed optical communications
Mueller, T., Xia, F., & Avouris, P. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.40 · Cited by 2,474
High-responsivity graphene/silicon-heterostructure waveguide photodetectors
Wang, X., Cheng, Z., Xu, K., Tsang, H. K., & Xu, J.-B. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.241 · Cited by 873
Cited by
Mixed-dimensional van der Waals heterostructures
Jariwala, D., Marks, T. J., & Hersam, M. C. (2017) · Nature Materials · doi:10.1038/nmat4703 · Cited by 1,606
High Detectivity Graphene‐Silicon Heterojunction Photodetector
Li, X., Zhu, M., Du, M., Lv, Z., Zhang, L., Li, Y., Yang, Y., Yang, T., Li, X., Wang, K., et al. (2016) · Small · doi:10.1002/smll.201502336 · Cited by 512
Liu, Y., Zhang, Y., Yang, Z., Yang, D., Ren, X., Pang, L., & Liu, S. (. (2016) · Advanced Materials · doi:10.1002/adma.201601995 · Cited by 386
Infrared Photodetectors Based on 2D Materials and Nanophotonics
Zha, J., Luo, M., Ye, M., Ahmed, T., Yu, X., Lien, D., He, Q., Lei, D., Ho, J. C., Bullock, J., et al. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202111970 · Cited by 331
Self-citationWan, X., Xu, Y., Guo, H., Shehzad, K., Ali, A., Liu, Y., Yang, J., Dai, D., Lin, C.-T., Liu, L., et al. (2017) · npj 2D Materials and Applications · doi:10.1038/s41699-017-0008-4 · Cited by 316
Self-citation
Metadata
- Authors
- Miao, J., Hu, W., Guo, N., Lu, Z., Liu, X., Liao, L., Chen, P., Jiang, T., Wu, S., Ho, J. C., Wang, L., Chen, X., & Lu, W.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2014-10-31
- Volume
- 11
- Issue
- 8
- Pages
- 936-942
- ISSN
- 1613-6810 (ISSN-L)
- OpenAlex
- W2120632946
- Cited by
- 195
- References
- 3
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Responsivity Graphene/InAs Nanowire Heterojunction Near-Infrared Photodetectors with Distinct Photocurrent On/Off Ratios. https://app.cochat.ai/papers/10.1002/smll.201402312
- The paper
- Miao, J., Hu, W., Guo, N., Lu, Z., Liu, X., Liao, L., Chen, P., Jiang, T., Wu, S., Ho, J. C., Wang, L., Chen, X., & Lu, W. (2015). High-Responsivity Graphene/InAs Nanowire Heterojunction Near-Infrared Photodetectors with Distinct Photocurrent On/Off Ratios. Small. https://doi.org/10.1002/smll.201402312
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.