Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Ratiometric Sensor Using Single Chirality Near‐Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring

Open access
Giraldo, Juan P., Landry, Markita P., Kwak, Seon‐Yeong, Jain, Rishabh M., Wong, Min Hao, Iverson, Nicole M., Ben‐Naim, Micha, Strano, Michael S.·2015·Small

Abstract

Advances in the separation and functionalization of single walled carbon nanotubes (SWCNT) by their electronic type have enabled the development of ratiometric fluorescent SWCNT sensors for the first time. Herein, single chirality SWCNT are independently functionalized to recognize either nitric oxide (NO), hydrogen peroxide (H 2 O 2), or no analyte (remaining invariant) to create optical sensor responses from the ratio of distinct emission peaks. This ratiometric approach provides a measure of analyte concentration, invariant to the absolute intensity emitted from the sensors and hence, more stable to external noise and detection geometry. Two distinct ratiometric sensors are demonstrated: one version for H 2 O 2, the other for NO, each using 7,6 emission, and each containing an invariant 6,5 emission wavelength. To functionalize these sensors from SWCNT isolated from the gel separation technique, a method for rapid and efficient coating exchange of single chirality sodium dodecyl sulfate‐SWCNT is introduced. As a proof of concept, spatial and temporal patterns of the ratio sensor response to H 2 O 2 and, separately, NO, are monitored in leaves of living plants in real time. This ratiometric optical sensing platform can enable the detection of trace analytes in complex environments such as strongly scattering media and biological tissues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/smll.201403276

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 187

Metadata

Authors
Giraldo, J. P., Landry, M. P., Kwak, S., Jain, R. M., Wong, M. H., Iverson, N. M., Ben‐Naim, M., & Strano, M. S.
Venue
Small
Publisher
Wiley
Published
2015-05-15
Volume
11
Issue
32
Pages
3973-3984
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W2108581465
Cited by
187
References
1
FWCI
5.20
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Ratiometric Sensor Using Single Chirality Near‐Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring. https://app.cochat.ai/papers/10.1002/smll.201403276
The paper
Giraldo, J. P., Landry, M. P., Kwak, S., Jain, R. M., Wong, M. H., Iverson, N. M., Ben‐Naim, M., & Strano, M. S. (2015). A Ratiometric Sensor Using Single Chirality Near‐Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring. Small. https://doi.org/10.1002/smll.201403276

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.