The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Long‐Term Real‐Time In Vivo Drug Release Monitoring with AIE Thermogelling Polymer
Open accessAbstract
A new drug concentration meter is developed. In vivo drug release can be monitored precisely via a self-indicating drug delivery system consisting of a new aggregation-induced emission thermoresponsive hydrogel. By taking the advantage of a self-indicating system, one can easily detect the depletion of drugs, and reinject to maintain a dosage in the optimal therapeutic window.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggregation-induced emission of 1-methyl-1,2,3,4,5-pentaphenylsilole
Luo, J., Xie, Z., Lam, J. W. Y., Cheng, L., Tang, B. Z., Chen, H., Qiu, C., Kwok, H. S., Zhan, X., Liu, Y., et al. (2001) · Chemical Communications · doi:10.1039/b105159h · Cited by 8,358
Self-citationInjectable hydrogels as unique biomedical materials
Yu, L., & Ding, J. (2008) · Chemical Society Reviews · doi:10.1039/b713009k · Cited by 1,545
Xue, X., Zhao, Y., Dai, L., Zhang, X., Hao, X., Zhang, C., Huo, S., Liu, J., Liu, C., Kumar, A., et al. (2014) · Advanced Materials · doi:10.1002/adma.201302365 · Cited by 206
Verma, N. K., Conroy, J., Lyons, P. E., Coleman, J., O'Sullivan, M. P., Kornfeld, H., Kelleher, D., & Volkov, Y. (2012) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2012.08.023 · Cited by 68
Self-citation
Cited by
A mini review on hydrogels classification and recent developments in miscellaneous applications
Varaprasad, K., Raghavendra, G. M., Jayaramudu, T., Yallapu, M. M., & Sadiku, R. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.05.096 · Cited by 534
Hydrogel design strategies for drug delivery
Dreiss, C. A. (2020) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2020.02.001 · Cited by 356
PEG-based thermosensitive and biodegradable hydrogels
Shi, J., Yu, L., & Ding, J. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.04.009 · Cited by 341
Cheng, H., Wu, Z., Wu, C., Wang, X., Liow, S. S., Li, Z., & Wu, Y.-L. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.08.075 · Cited by 119
Self-citationAIE polymers in sensing, imaging and theranostic applications
Hu, R., Yang, X., Qin, A., & Tang, B. Z. (2021) · Materials Chemistry Frontiers · doi:10.1039/d1qm00078k · Cited by 103
Self-citation
Metadata
- Authors
- Liow, S. S., Dou, Q., Kai, D., Li, Z., Sugiarto, S., Yu, C. Y. Y., Kwok, R. T. K., Chen, X., Wu, Y., Ong, S. T., Kizhakeyil, A., Verma, N. K., Tang, B. Z., & Loh, X. J.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2016-12-08
- Volume
- 13
- Issue
- 7
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2559981765
- Cited by
- 207
- References
- 4
- FWCI
- 17.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long‐Term Real‐Time In Vivo Drug Release Monitoring with AIE Thermogelling Polymer. https://app.cochat.ai/papers/10.1002/smll.201603404
- The paper
- Liow, S. S., Dou, Q., Kai, D., Li, Z., Sugiarto, S., Yu, C. Y. Y., Kwok, R. T. K., Chen, X., Wu, Y., Ong, S. T., Kizhakeyil, A., Verma, N. K., Tang, B. Z., & Loh, X. J. (2017). Long‐Term Real‐Time In Vivo Drug Release Monitoring with AIE Thermogelling Polymer. Small. https://doi.org/10.1002/smll.201603404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.