Anisotropically Aligned Cell‐Laden Nanofibrous Bundle Fabricated via Cell Electrospinning to Regenerate Skeletal Muscle Tissue
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For muscle regeneration, a uniaxially arranged micropattern is important to mimic the structure of the natural extracellular matrix. Recently, cell electrospinning (CE) has been tested to fabricate cell‐laden fibrous structures by embedding cells directly into micro/nanofibers. Although homogenous cell distribution and a reasonable cell viability of the cell‐laden fibrous structure fabricated using the CE process are achieved, unique topographical cues formed by an aligned fibrous structure have not been applied. In this study, a CE process to achieve not only homogeneous cell distribution with a high cell viability, but also highly aligned cells, which are guided by aligned alginate fibers is employed. To attain the aligned cell‐laden fibrous structure, various processing conditions are examined. The selected condition is applied using C2C12 myoblast cells to ensure the biocompatibility and guidance of cell elongation and alignment. As a control, a cell‐printed scaffold using a 3D bioprinter is used to compare the efficiency of cell alignment and differentiation of myoblasts. Highly arranged, multinucleated cell morphology is confirmed in the CE scaffold, which successively facilitates myogenic differentiation. It is believed that this study will be a new platform for obtaining cell alignment and will significantly benefit the efforts on muscle regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 3D bioprinting system to produce human-scale tissue constructs with structural integrity
Kang, H.-W., Lee, S. J., Ko, I. K., Kengla, C., Yoo, J. J., & Atala, A. (2016) · Nature Biotechnology · doi:10.1038/nbt.3413 · Cited by 2,622
Cited by
Hydrogels for Tissue Engineering: Addressing Key Design Needs Toward Clinical Translation
Xu, F., Dawson, C., Lamb, M., Mueller, E., Stefanek, E., Akbari, M., & Hoare, T. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.849831 · Cited by 209
“As another example (Figure 6C), C2C12 myoblasts were electrospun in water with alginate and PEO (electrospinning aid) and then crosslinked in a calcium ion/DMEM bath for 2min to produce hydrogel nanofibers with aligned morphologies (Yeo and Kim, 2018).”
MethodCell-Electrospinning and Its Application for Tissue Engineering
Hong, J., Yeo, M., Yang, G. H., & Kim, G. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20246208 · Cited by 185
“Figure adapted with permission from [30].”
BackgroundMethodInfluentialSelf-citationHydrogel-Based Fiber Biofabrication Techniques for Skeletal Muscle Tissue Engineering
Volpi, M., Paradiso, A., Costantini, M., & Świȩszkowski, W. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c01145 · Cited by 163
Collagen based electrospun materials for skin wounds treatment
Hernández‐Rangel, A., & Martin‐Martinez, E. S. (2021) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37154 · Cited by 133
Rapid fabrication of collagen bundles mimicking tumor-associated collagen architectures
Gong, X., Kulwatno, J., & Mills, K. L. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.03.019 · Cited by 43
Qiu, Z., Zhu, H., Wang, Y., Kasimu, A., Li, D., & He, J. (2023) · Bio-Design and Manufacturing · doi:10.1007/s42242-022-00225-z · Cited by 36
Metadata
- Authors
- Yeo, M., & Kim, G. H.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2018-10-11
- Volume
- 14
- Issue
- 48
- Pages
- e1803491-e1803491
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2896646970
- Cited by
- 118
- References
- 1
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.