Optical Sensor for Real-Time pH Monitoring in Human Tissue

Wencel, Dorota, Kaworek, Alicja, Abel, Tobias, Efremov, Vitaly, Bradford, Aidan, Carthy, Denise, Coady, Garret, McMorrow, Roger C. N. +1 more·2018·Small

Abstract

This article reports on a fiber-based ratiometric optical pH sensor for use in real-time and continuous in vivo pH monitoring in human tissue. Stable hybrid sol-gel-based pH sensing material is deposited on a highly flexible plastic optical fiber tip and integrated with excitation and detection electronics. The sensor is extensively tested in a laboratory environment before it is applied in vivo in a human model. The pH sensor performance in the laboratory environment outperforms the state-of-the-art reported in the current literature. It exhibits the highest sensitivity in the physiological pH range, resolution of 0.0013 pH units, excellent sensor to sensor reproducibility, long-term stability, short response time of <2 min, and drift of 0.003 pH units per 22 h. The sensor also exhibits promising performance in in vitro whole blood samples. In addition, human evaluations conducted under this project demonstrate successful short-term deployment of this sensor in vivo.

Integrity signals

Registry

Crossref · 10.1002/smll.201803627

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Fiber optic ratiometric sensors with a hybrid sol-gel pH sensing material on a flexible POF tip can measure in vivo pH in the physiological range with a resolution of 0.0013 pH units.

    “The use of fiber optic sensors for in vivo pH measurement is possible using ratiometric sensors based on a hybrid sol-gel pH sensing material deposited on a highly flexible POF tip capable of operating in the physiological pH range with a resolution of 0.0013 pH units.”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [225]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wencel, D., Kaworek, A., Abel, T., Efremov, V., Bradford, A., Carthy, D., Coady, G., McMorrow, R. C. N., & McDonagh, C.
Affiliations
  • Dublin City University (IE)
  • BlueBridge Technologies 3015 Lake Drive, Citywest Campus, Citywest Dublin 24 Ireland
  • F. Hoffmann-La Roche AG (CH)
  • Royal College of Surgeons in Ireland (IE)
  • National Maternity Hospital (IE)
Corresponding author
Wencel, Dorota
Venue
Small
Publisher
Wiley
Published
2018-11-14
Volume
14
Issue
51
Pages
e1803627-e1803627
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W2901730896
Cited by
77
References
33
Citations by year
2026: 9 · 2025: 12 · 2024: 11 · 2023: 7 · 2022: 10 · 2021: 15 · 2020: 8 · 2019: 5
FWCI
4.23
Type
journal article
Language
en
Open access
closed
Locations
  • Small (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Enterprise Ireland (IP 2012 0181, IP 2014 0300A)
  • Science Foundation Ireland (14/IFB/2704)
Topics
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
Keywords
optical pH sensor, ratiometric sensing, fiber optic sensors, human tissue, sensor stability, real-time monitoring
MeSH terms
Fiber Optic Technology, Humans, Hydrogen-Ion Concentration, Optical Fibers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review