Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Recent Progress in Time‐Resolved Biosensing and Bioimaging Based on Lanthanide‐Doped Nanoparticles

Ma, Qinqin, Wang, Jie, Li, Zhiheng, Lv, Xiaobo, Liang, Ling, Yuan, Quan·2019·Small

Abstract

Luminescent nanomaterials have attracted great attention in luminescence‐based bioanalysis due to their abundant optical and tunable surface physicochemical properties. However, luminescent nanomaterials often suffer from serious autofluorescence and light scattering interference when applied to complex biological samples. Time‐resolved luminescence methodology can efficiently eliminate autofluorescence and light scattering interference by collecting the luminescence signal of a long‐lived probe after the background signals decays completely. Lanthanides have a unique [Xe]4fN electronic configuration and ladder‐like energy states, which endow lanthanide‐doped nanoparticles with many desirable optical properties, such as long luminescence lifetimes, large Stokes/anti‐Stokes shifts, and sharp emission bands. Due to their long luminescence lifetimes, lanthanide‐doped nanoparticles are widely used for high‐sensitive biosensing and high‐contrast bioimaging via time‐resolved luminescence methodology. In this review, recent progress in the development of lanthanide‐doped nanoparticles and their application in time‐resolved biosensing and bioimaging are summarized. At the end of this review, the current challenges and perspectives of lanthanide‐doped nanoparticles for time‐resolved bioapplications are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/smll.201804969

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 163

Metadata

Authors
Ma, Q., Wang, J., Li, Z., Lv, X., Liang, L., & Yuan, Q.
Venue
Small
Publisher
Wiley
Published
2019-02-14
Volume
15
Issue
32
Pages
e1804969-e1804969
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W2912800773
Cited by
163
References
4
FWCI
6.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recent Progress in Time‐Resolved Biosensing and Bioimaging Based on Lanthanide‐Doped Nanoparticles. https://app.cochat.ai/papers/10.1002/smll.201804969
The paper
Ma, Q., Wang, J., Li, Z., Lv, X., Liang, L., & Yuan, Q. (2019). Recent Progress in Time‐Resolved Biosensing and Bioimaging Based on Lanthanide‐Doped Nanoparticles. Small. https://doi.org/10.1002/smll.201804969

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.