The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
A MXene‐Based Wearable Biosensor System for High‐Performance In Vitro Perspiration Analysis
Abstract
Wearable electrochemical biosensors for sweat analysis present a promising means for noninvasive biomarker monitoring. However, sweat‐based sensing still poses several challenges, including easy degradation of enzymes and biomaterials with repeated testing, limited detection range and sensitivity of enzyme‐based biosensors caused by oxygen deficiency in sweat, and poor shelf life of sensors using all‐in‐one working electrodes patterned by traditional techniques (e.g., electrodeposition and screen printing). Herein, a stretchable, wearable, and modular multifunctional biosensor is developed, incorporating a novel MXene/Prussian blue (Ti 3 C 2 Tx/PB) composite designed for durable and sensitive detection of biomarkers (e.g., glucose and lactate) in sweat. A unique modular design enables a simple exchange of the specific sensing electrode to target the desired analytes. Furthermore, an implemented solid–liquid–air three‐phase interface design leads to superior sensor performance and stability. Typical electrochemical sensitivities of 35.3 µA m m−1 cm−2 for glucose and 11.4 µA m m−1 cm−2 for lactate are achieved using artificial sweat. During in vitro perspiration monitoring of human subjects, the physiochemistry signals (glucose and lactate level) can be measured simultaneously with high sensitivity and good repeatability. This approach represents an important step toward the realization of ultrasensitive enzymatic wearable biosensors for personalized health monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale pattern growth of graphene films for stretchable transparent electrodes
Kim, K. S., Zhao, Y., Jang, H., Lee, S. Y., Kim, J. M., Kim, K. S., Ahn, J.-H., Kim, P., Choi, J.-Y., & Hong, B. H. (2009) · Nature · doi:10.1038/nature07719 · Cited by 10,452
2D metal carbides and nitrides (MXenes) for energy storage
Anasori, B., Lukatskaya, M. R., & Gogotsi, Y. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.98 · Cited by 7,440
25th Anniversary Article: MXenes: A New Family of Two‐Dimensional Materials
Naguib, M., Mochalin, V. N., Barsoum, M. W., & Gogotsi, Y. (2014) · Advanced Materials · doi:10.1002/adma.201304138 · Cited by 6,414
Electromagnetic interference shielding with 2D transition metal carbides (MXenes)
Shahzad, F., Alhabeb, M., Hatter, C. B., Anasori, B., Man Hong, S., Koo, C. M., & Gogotsi, Y. (2016) · Science · doi:10.1126/science.aag2421 · Cited by 5,201
Recent Advances in Ultrathin Two-Dimensional Nanomaterials
Tan, C., Cao, X., Wu, X.-J., He, Q., Yang, J., Zhang, X., Chen, J., Zhao, W., Han, S., Nam, G.-H., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00558 · Cited by 5,100
Self-citationFully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Cation Intercalation and High Volumetric Capacitance of Two-Dimensional Titanium Carbide
Lukatskaya, M. R., Mashtalir, O., Ren, C. E., Dall’Agnese, Y., Rozier, P., Taberna, P. L., Naguib, M., Simon, P., Barsoum, M. W., & Gogotsi, Y. (2013) · Science · doi:10.1126/science.1241488 · Cited by 4,320
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Ultra-high-rate pseudocapacitive energy storage in two-dimensional transition metal carbides
Lukatskaya, M. R., Kota, S., Lin, Z., Zhao, M.-Q., Shpigel, N., Levi, M. D., Halim, J., Taberna, P.-L., Barsoum, M. W., Simon, P., et al. (2017) · Nature Energy · doi:10.1038/nenergy.2017.105 · Cited by 2,335
Ran, J., Gao, G., Li, F.-T., Ma, T.-Y., Du, A., & Qiao, S.-Z. (2017) · Nature Communications · doi:10.1038/ncomms13907 · Cited by 2,023
Cited by
Muscle-Inspired Self-Healing Hydrogels for Strain and Temperature Sensor
Ge, G., Lu, Y., Qu, X., Zhao, W., Ren, Y., Wang, W., Wang, Q., Huang, W., & Dong, X. (2020) · ACS Nano · doi:10.1021/acsnano.9b07874 · Cited by 732
Self-citationSensing with MXenes: Progress and Prospects
Ho, D. H., Choi, Y. Y., Jo, S. B., Myoung, J., & Cho, J. H. (2021) · Advanced Materials · doi:10.1002/adma.202005846 · Cited by 482
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Deshmukh, K., Kovářík, T., & Khadheer Pasha, S. K. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213514 · Cited by 282
Metadata
- Authors
- Lei, Y., Zhao, W., Zhang, Y., Jiang, Q., He, J., Baeumner, A. J., Wolfbeis, O. S., Wang, Z. L., Salama, K. N., & Alshareef, H. N.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2019-04-08
- Volume
- 15
- Issue
- 19
- Pages
- e1901190-e1901190
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2938816672
- Cited by
- 441
- References
- 49
- FWCI
- 17.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A MXene‐Based Wearable Biosensor System for High‐Performance In Vitro Perspiration Analysis. https://app.cochat.ai/papers/10.1002/smll.201901190
- The paper
- Lei, Y., Zhao, W., Zhang, Y., Jiang, Q., He, J., Baeumner, A. J., Wolfbeis, O. S., Wang, Z. L., Salama, K. N., & Alshareef, H. N. (2019). A MXene‐Based Wearable Biosensor System for High‐Performance In Vitro Perspiration Analysis. Small. https://doi.org/10.1002/smll.201901190
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.