Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 441

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

A MXene‐Based Wearable Biosensor System for High‐Performance In Vitro Perspiration Analysis

Lei, Yongjiu, Zhao, Wenli, Zhang, Yizhou, Jiang, Qiu, He, Jr‐Hau, Baeumner, Antje J., Wolfbeis, Otto S., Wang, Zhong Lin, Salama, Khaled N., Alshareef, Husam N.·2019·Small

Abstract

Wearable electrochemical biosensors for sweat analysis present a promising means for noninvasive biomarker monitoring. However, sweat‐based sensing still poses several challenges, including easy degradation of enzymes and biomaterials with repeated testing, limited detection range and sensitivity of enzyme‐based biosensors caused by oxygen deficiency in sweat, and poor shelf life of sensors using all‐in‐one working electrodes patterned by traditional techniques (e.g., electrodeposition and screen printing). Herein, a stretchable, wearable, and modular multifunctional biosensor is developed, incorporating a novel MXene/Prussian blue (Ti 3 C 2 Tx/PB) composite designed for durable and sensitive detection of biomarkers (e.g., glucose and lactate) in sweat. A unique modular design enables a simple exchange of the specific sensing electrode to target the desired analytes. Furthermore, an implemented solid–liquid–air three‐phase interface design leads to superior sensor performance and stability. Typical electrochemical sensitivities of 35.3 µA m m−1 cm−2 for glucose and 11.4 µA m m−1 cm−2 for lactate are achieved using artificial sweat. During in vitro perspiration monitoring of human subjects, the physiochemistry signals (glucose and lactate level) can be measured simultaneously with high sensitivity and good repeatability. This approach represents an important step toward the realization of ultrasensitive enzymatic wearable biosensors for personalized health monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/smll.201901190

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Cited by

See all 441

Metadata

Authors
Lei, Y., Zhao, W., Zhang, Y., Jiang, Q., He, J., Baeumner, A. J., Wolfbeis, O. S., Wang, Z. L., Salama, K. N., & Alshareef, H. N.
Venue
Small
Publisher
Wiley
Published
2019-04-08
Volume
15
Issue
19
Pages
e1901190-e1901190
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W2938816672
Cited by
441
References
49
FWCI
17.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A MXene‐Based Wearable Biosensor System for High‐Performance In Vitro Perspiration Analysis. https://app.cochat.ai/papers/10.1002/smll.201901190
The paper
Lei, Y., Zhao, W., Zhang, Y., Jiang, Q., He, J., Baeumner, A. J., Wolfbeis, O. S., Wang, Z. L., Salama, K. N., & Alshareef, H. N. (2019). A MXene‐Based Wearable Biosensor System for High‐Performance In Vitro Perspiration Analysis. Small. https://doi.org/10.1002/smll.201901190

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.