The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Flexible Smart Noncontact Control Systems with Ultrasensitive Humidity Sensors
Abstract
The development of noncontact humidity sensors with high sensitivity, rapid response, and a facile fabrication process is urgently desired for advanced noncontact human–machine interaction (HMI) applications. Here, a flexible and transparent humidity sensor based on MoO 3 nanosheets is developed with a low‐cost and easily manufactured process. The designed humidity sensor exhibits ultrahigh sensitivity, fast response, great stability, and high selectivity, exceeding the state‐of‐the‐art humidity sensors. Furthermore, a wearable moisture analysis system is assembled for real‐time monitoring of ambient humidity and human breathing states. Benefiting from the sensitive and rapid response to fingertip humidity, the sensors are successfully applied to both a smart noncontact multistage switch and a novel flexible transparent noncontact screen for smart mobile devices, demonstrating the potential of the MoO 3 nanosheets‐based humidity sensors in future HMI systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Porous Ionic Membrane Based Flexible Humidity Sensor and its Multifunctional Applications
Li, T., Li, L., Sun, H., Xu, Y., Wang, X., Luo, H., Liu, Z., & Zhang, T. (2017) · Advanced Science · doi:10.1002/advs.201600404 · Cited by 298
Cited by
Recent advances in humidity sensors for human body related humidity detection
Duan, Z., Jiang, Y., & Tai, H. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc04180k · Cited by 365
Qu, X., Liu, Z., Tan, P., Wang, C., Liu, Y., Feng, H., Luo, D., Li, Z., & Wang, Z. L. (2022) · Science Advances · doi:10.1126/sciadv.abq2521 · Cited by 353
Multifunctional Flexible Humidity Sensor Systems Towards Noncontact Wearable Electronics
Lu, Y., Yang, G., Shen, Y., Yang, H., & Xu, K. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00895-5 · Cited by 320
Guo, Y., Wei, X., Gao, S., Yue, W., Li, Y., & Shen, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104288 · Cited by 279
Self-citationPeng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224
Metadata
- Authors
- Yang, J., Shi, R., Lou, Z., Chai, R., Jiang, K., & Shen, G.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2019-08
- Volume
- 15
- Issue
- 38
- Pages
- e1902801-e1902801
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W2965064308
- Cited by
- 166
- References
- 6
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Smart Noncontact Control Systems with Ultrasensitive Humidity Sensors. https://app.cochat.ai/papers/10.1002/smll.201902801
- The paper
- Yang, J., Shi, R., Lou, Z., Chai, R., Jiang, K., & Shen, G. (2019). Flexible Smart Noncontact Control Systems with Ultrasensitive Humidity Sensors. Small. https://doi.org/10.1002/smll.201902801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.