Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 269

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Highly Morphology‐Controllable and Highly Sensitive Capacitive Tactile Sensor Based on Epidermis‐Dermis‐Inspired Interlocked Asymmetric‐Nanocone Arrays for Detection of Tiny Pressure

Niu, Hongsen, Gao, Song, Yue, Wenjing, Li, Yang, Zhou, Weijia, Liu, Hong·2020·Small

Abstract

The tactile sensor lies at the heart of electronic skin and is of great importance in the development of flexible electronic devices. To date, it still remains a critical challenge to develop a large‐scale capacitive tactile sensor with high sensitivity and controllable morphology in an economical way. Inspired by the interlocked microridges between the epidermis and dermis, herein, a highly sensitive capacitive tactile sensor by creating interlocked asymmetric‐nanocones in poly(vinylidenefluoride‐co‐trifluoroethylene) film is proposed. Particularly, a facile method based on cone‐shaped nanoporous anodized aluminum oxide templates is proposed to cost‐effectively fabricate the highly ordered nanocones in a controllable manner and on a large scale. Finite‐element analysis reveals that under vertical forces, the strain/stress can be highly strengthened and localized at the contact apexes, resulting in an amplified variation of film permittivity and thickness. Benefiting from this, the developed tactile sensor presents several conspicuous features, including the maximum sensitivity (6.583 kPa−1) in the low pressure region (0–100 Pa), ultralow detection limit (≈3 Pa), rapid response/recovery time (48/36 ms), excellent stability and reproducibility (10 000 cycles). These salient merits enable the sensor to be successfully applied in a variety of applications including sign language gesture detection, spatial pressure mapping, Braille recognition, and physiological signal monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/smll.201904774

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 269

Metadata

Authors
Niu, H., Gao, S., Yue, W., Li, Y., Zhou, W., & Liu, H.
Venue
Small
Publisher
Wiley
Published
2019-12-29
Volume
16
Issue
4
Pages
e1904774-e1904774
ISSN
  • 1613-6810 (ISSN-L)
  • 1613-6829
OpenAlex
W2998705016
Cited by
269
References
56
FWCI
8.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Morphology‐Controllable and Highly Sensitive Capacitive Tactile Sensor Based on Epidermis‐Dermis‐Inspired Interlocked Asymmetric‐Nanocone Arrays for Detection of Tiny Pressure. https://app.cochat.ai/papers/10.1002/smll.201904774
The paper
Niu, H., Gao, S., Yue, W., Li, Y., Zhou, W., & Liu, H. (2020). Highly Morphology‐Controllable and Highly Sensitive Capacitive Tactile Sensor Based on Epidermis‐Dermis‐Inspired Interlocked Asymmetric‐Nanocone Arrays for Detection of Tiny Pressure. Small. https://doi.org/10.1002/smll.201904774

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.