Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.

Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing

Open access

Abstract

Mechanosensation electronics (or Electronic skin, e-skin) consists of mechanically flexible and stretchable sensor networks that can detect and quantify various stimuli to mimic the human somatosensory system, with the sensations of touch, heat/cold, and pain in skin through various sensory receptors and neural pathways. Here we present a skin-inspired highly stretchable and conformable matrix network (SCMN) that successfully expands the e-skin sensing functionality including but not limited to temperature, in-plane strain, humidity, light, magnetic field, pressure, and proximity. The actualized specific expandable sensor units integrated on a structured polyimide network, potentially in three-dimensional (3D) integration scheme, can also fulfill simultaneous multi-stimulus sensing and achieve an adjustable sensing range and large-area expandability. We further construct a personalized intelligent prosthesis and demonstrate its use in real-time spatial pressure mapping and temperature estimation. Looking forward, this SCMN has broader applications in humanoid robotics, new prosthetics, human–machine interfaces, and health-monitoring technologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-017-02685-9

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Skin-inspired highly stretchable and conformable matrix networks. a Schematic illustration of SCMNs conforming to the surface of a human arm and an expanded network (expansion: 200%) conforming to the surface of a human abdomen (right); the tree branch-like connections of neurons (left bottom); the sensory receptors of the glabrous skin (left top). b Optical image of the fabricated polyimide network (10 × 10 array, scale bar: 5 mm). c Tilted SEM image of the polyimide network (scale bar: 500 μm); the inset is a higher resolution SEM image of a meandering interconnect (scale bar: 50 μm). d Schematic layout of an SCMN—an integrated sensor array with eight functions. (temp.: temperature). e Image of an SCMN attached to a sheet of paper, demonstrating ultrahigh flexibility and stretchability. The inset (upper) shows an SCMN conforming to a human finger, (middle) an SCMN attached to human skin with compression, and (bottom) an SCMN stretched by a human hand (scale bar: 1 cm)
Fig. 1 Skin-inspired highly stretchable and conformable matrix networks. a Schematic illustration of SCMNs conforming to the surface of a human arm and an expanded network (expansion: 200%) conforming to the surface of a human abdomen (right); the tree branch-like connections of neurons (left bottom); the sensory receptors of the glabrous skin (left top). b Optical image of the fabricated polyimide network (10 × 10 array, scale bar: 5 mm). c Tilted SEM image of the polyimide network (scale bar: 500 μm); the inset is a higher resolution SEM image of a meandering interconnect (scale bar: 50 μm). d Schematic layout of an SCMN—an integrated sensor array with eight functions. (temp.: temperature). e Image of an SCMN attached to a sheet of paper, demonstrating ultrahigh flexibility and stretchability. The inset (upper) shows an SCMN conforming to a human finger, (middle) an SCMN attached to human skin with compression, and (bottom) an SCMN stretched by a human hand (scale bar: 1 cm)CC BY · PubMed Central
Fig. 2 Mechanical and electrical testing of the meandering interconnects. a Relative resistance and tensile force change with the extension of the meandering interconnects (50-μm-wide, 50-μm-thick polyimide wire coated with Ag thin films); the green section shows a perfectly stable performance region, and the inset depicts a schematic of the customized stretch-testing platform. b Optical images of a meandering wire stretched from an L/L0 of 1 to 8 (scale bar: 3 mm). c Durability testing at 300% expansion, with an inset showing the stretching at L/L0 = 1 and L/L0 = 3. d Relative resistance change vs. bend radius, with an inset showing bend durability at a bend radius of 150 μm. e Optical image of an expanding SCMN (scale bar: 2 cm), with an inset depicting an enlarged view of the red rectangle (scale bar: 5 mm). The network is made of 100 nodes (1.6 mm in diameter) connected by 50-μm-wide, 25-μm-thick polyimide wires coated with Au thin films. f Optical image of a twisted SCMN (scale bar: 2 cm)
Fig. 2 Mechanical and electrical testing of the meandering interconnects. a Relative resistance and tensile force change with the extension of the meandering interconnects (50-μm-wide, 50-μm-thick polyimide wire coated with Ag thin films); the green section shows a perfectly stable performance region, and the inset depicts a schematic of the customized stretch-testing platform. b Optical images of a meandering wire stretched from an L/L0 of 1 to 8 (scale bar: 3 mm). c Durability testing at 300% expansion, with an inset showing the stretching at L/L0 = 1 and L/L0 = 3. d Relative resistance change vs. bend radius, with an inset showing bend durability at a bend radius of 150 μm. e Optical image of an expanding SCMN (scale bar: 2 cm), with an inset depicting an enlarged view of the red rectangle (scale bar: 5 mm). The network is made of 100 nodes (1.6 mm in diameter) connected by 50-μm-wide, 25-μm-thick polyimide wires coated with Au thin films. f Optical image of a twisted SCMN (scale bar: 2 cm)CC BY · PubMed Central
Fig. 3 Multifunctional sensing performances. a, b Temperature sensing. a The relative resistance of the temperature sensor changes linearly with temperature; the inset depicts a Pt thin film temperature sensor fabricated on an SCMN. b Spatial temperature distribution recognition for temperatures close to 36.8 °C and 45.8 °C after placing a heat source above an SCMN. c, d In-plane strain sensing. c The relative resistance change increases with increasing applied strain; the inset shows a Constantan alloy thin film in-plane strain sensor mounted on an SCMN. (Error bars represent the fluctuation between normalized resistance and applied strain at each point.) d The temporal resistance changes for different curvatures of the strain sensor under cyclical bending (Strain: 0.7%, 1.3% and 1.5%). e, f Humidity sensing. e The change in capacitance is linear with increasing relative humidity (RH); the inset is an image of a humidity sensor on an SCMN. f Image of water droplets covering a partial area of a humidity senor array (left) and a corresponding map of the regional capacitance change (right). The red circles indicate where the droplets are placed. g, h Light sensing. g The photocurrent generated by UV light (355 nm) increases linearly with the light intensity; inset is an image of an optical sensor. h Repeatable UV response under different illumination intensities at a 5 V bias. i, j Magnetic sensing. i The GMR characteristics of a Co/Cu magnetic sensor; inset is an image of a magnetic sensor on an SCMN. j The recorded resistance changes when a magnet cyclically approaches (pink) and withdraws (white) from the sensor. Inset scale bars: 500 μm
Fig. 3 Multifunctional sensing performances. a, b Temperature sensing. a The relative resistance of the temperature sensor changes linearly with temperature; the inset depicts a Pt thin film temperature sensor fabricated on an SCMN. b Spatial temperature distribution recognition for temperatures close to 36.8 °C and 45.8 °C after placing a heat source above an SCMN. c, d In-plane strain sensing. c The relative resistance change increases with increasing applied strain; the inset shows a Constantan alloy thin film in-plane strain sensor mounted on an SCMN. (Error bars represent the fluctuation between normalized resistance and applied strain at each point.) d The temporal resistance changes for different curvatures of the strain sensor under cyclical bending (Strain: 0.7%, 1.3% and 1.5%). e, f Humidity sensing. e The change in capacitance is linear with increasing relative humidity (RH); the inset is an image of a humidity sensor on an SCMN. f Image of water droplets covering a partial area of a humidity senor array (left) and a corresponding map of the regional capacitance change (right). The red circles indicate where the droplets are placed. g, h Light sensing. g The photocurrent generated by UV light (355 nm) increases linearly with the light intensity; inset is an image of an optical sensor. h Repeatable UV response under different illumination intensities at a 5 V bias. i, j Magnetic sensing. i The GMR characteristics of a Co/Cu magnetic sensor; inset is an image of a magnetic sensor on an SCMN. j The recorded resistance changes when a magnet cyclically approaches (pink) and withdraws (white) from the sensor. Inset scale bars: 500 μmCC BY · PubMed Central
Fig. 4 Pressure and proximity sensing performances and area expansion. a Capacitance response to various pressures for two consecutive load tests. b Real-time small-pressure recording during the sequential application of six water droplets to the sensor; the corresponding pressure is 7.3 ± 1.2 Pa. c Pressure mapping of a number “6” stamped on the pressure sensor array with a pressure of 8 kPa. d Capacitance changes from a finger cyclically approaching the device (green, from a distance of approximately 1 cm), pressing it (pink) and moving away (white). e The relative capacitance change reduces with the decreasing distance of an approaching finger. The inset shows the capacitance difference as a finger repeatedly approaches the device. f Proximity detection of a hand and identification of its position. g Schematic illustration of an SCMN as an artificial electronic skin on a hand, showing sensing adjustability and expandability (scale bar: 1 cm). h Pressure mapping before and after the 300% expansion of an SCMN; the position of the pressure load is also identified after expansion
Fig. 4 Pressure and proximity sensing performances and area expansion. a Capacitance response to various pressures for two consecutive load tests. b Real-time small-pressure recording during the sequential application of six water droplets to the sensor; the corresponding pressure is 7.3 ± 1.2 Pa. c Pressure mapping of a number “6” stamped on the pressure sensor array with a pressure of 8 kPa. d Capacitance changes from a finger cyclically approaching the device (green, from a distance of approximately 1 cm), pressing it (pink) and moving away (white). e The relative capacitance change reduces with the decreasing distance of an approaching finger. The inset shows the capacitance difference as a finger repeatedly approaches the device. f Proximity detection of a hand and identification of its position. g Schematic illustration of an SCMN as an artificial electronic skin on a hand, showing sensing adjustability and expandability (scale bar: 1 cm). h Pressure mapping before and after the 300% expansion of an SCMN; the position of the pressure load is also identified after expansionCC BY · PubMed Central
Fig. 5 Simultaneous multiple-stimuli sensing performances. a Real-time simultaneous sensing of temperature, pressure, and proximity stimuli. Signals in recording: Proximity—artificial/human hand approaches the SCMN with a distance of about 1 cm; Pressure—loading bottles on the SCMN with pressures of 2.4 kPa (empty), 4 kPa (filled with water), and 3.2 kPa (filled with hot water) consecutively; Contact—human hand on the SCMN; and Exhale—human breaths toward the SCMN for three times (Details are described in Supplementary Movie 4). b Real-time simultaneous sensing of magnetic field, pressure, and proximity stimuli. The detailed procedures of a permanent magnet put near or loaded on the SCMN: the magnet approaches the SCMN with a distance of about 1.5 cm; the proximity distances change between 1 cm and 2 cm alternatively; the magnet loaded on the SCMN corresponding to a pressure of 5 kPa (see Supplementary Movie 5)
Fig. 5 Simultaneous multiple-stimuli sensing performances. a Real-time simultaneous sensing of temperature, pressure, and proximity stimuli. Signals in recording: Proximity—artificial/human hand approaches the SCMN with a distance of about 1 cm; Pressure—loading bottles on the SCMN with pressures of 2.4 kPa (empty), 4 kPa (filled with water), and 3.2 kPa (filled with hot water) consecutively; Contact—human hand on the SCMN; and Exhale—human breaths toward the SCMN for three times (Details are described in Supplementary Movie 4). b Real-time simultaneous sensing of magnetic field, pressure, and proximity stimuli. The detailed procedures of a permanent magnet put near or loaded on the SCMN: the magnet approaches the SCMN with a distance of about 1.5 cm; the proximity distances change between 1 cm and 2 cm alternatively; the magnet loaded on the SCMN corresponding to a pressure of 5 kPa (see Supplementary Movie 5)CC BY · PubMed Central
Fig. 6 The intelligent prosthetic hand with personalized SCMN configuration. a Schematic illustration of human hand picking up a cup with temperature detection at the same time. b Images show operations of the intelligent prosthetic hand to grasp (upper) and release (bottom). The procedures of grasping/releasing are also shown in Supplementary Movie 6. The intelligent prosthetic hand equipped with five pressure sensors (P1, P2, P3, P4, and P5) and one temperature sensor (T0) on fingers. c Pressure distribution contour on the fingers when the intelligent prosthetic hand is grasping a water cup and sensing temperature of 59.1 °C. d–g The intelligent prosthetic hand grasps/releases cups filled with water with four different temperatures: 27 °C (d), 48 7 °C (e), 59.1 °C (f), and 71.2 °C (g). h Temperature estimation by the fitting equation when the intelligent prosthetic hand is grasping
Fig. 6 The intelligent prosthetic hand with personalized SCMN configuration. a Schematic illustration of human hand picking up a cup with temperature detection at the same time. b Images show operations of the intelligent prosthetic hand to grasp (upper) and release (bottom). The procedures of grasping/releasing are also shown in Supplementary Movie 6. The intelligent prosthetic hand equipped with five pressure sensors (P1, P2, P3, P4, and P5) and one temperature sensor (T0) on fingers. c Pressure distribution contour on the fingers when the intelligent prosthetic hand is grasping a water cup and sensing temperature of 59.1 °C. d–g The intelligent prosthetic hand grasps/releases cups filled with water with four different temperatures: 27 °C (d), 48 7 °C (e), 59.1 °C (f), and 71.2 °C (g). h Temperature estimation by the fitting equation when the intelligent prosthetic hand is graspingCC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 60 references

Research works printed but not linked: 1

  1. Purves, D. et al. (eds). in Neuroscience 2nd edn. (Sinauer Associates, Sunderland, MA, 2001). Available from: http://www.ncbi.nlm.nih.gov/books/NBK10895/.

Cited by

See all 1,413

Metadata

Authors
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L.
Affiliations
  • Chinese Academy of Sciences (CN)
  • Georgia Institute of Technology (US)
Corresponding author
  • Bao, Rongrong
  • Pan, Caofeng
  • Wang, Zhong Lin
Venue
Nature Communications
Published
2018-01-16
Volume
9
Issue
1
Pages
244-244
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2783338612
Cited by
1,413
References
60
Citations by year
2026: 72 · 2025: 132 · 2024: 181 · 2023: 184 · 2022: 204 · 2021: 222 · 2020: 184 · 2019: 161 · 2018: 73
FWCI
63.92
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
National Natural Science Foundation of China (51432005, 61505010 and 51502018, 51502018, 61505010, 61405040, 2016YFA0202703)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
Keywords
electronic skin, mechanosensing, pressure sensing, temperature sensing, humidity sensing, optical sensing, magnetic field sensing, proximity sensing, polyimide substrate, intelligent prosthesis, pressure mapping, human-machine interaction, health monitoring
MeSH terms
Humans, Humidity, Microscopy, Electron, Scanning, Pressure, Sensation, Skin, Skin Physiological Phenomena, Temperature, Biosensing Techniques, Mechanotransduction, Cellular, Mechanical Phenomena, Magnetic Fields

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing. https://app.cochat.ai/papers/10.1038/s41467-017-02685-9
The paper
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018). Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing. Nature Communications. https://doi.org/10.1038/s41467-017-02685-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.