CoChat

A design approach for semi-active and smart base-isolated buildings

Li, Hui, Ou, Jinping · 2006 · Structural Control and Health Monitoring
Cited by 47

The DOI matches its Crossref record.

Abstract

Hybrid isolation systems consisting of mainly a base isolation system and either active controllers or semi-active dampers or smart dampers or combination thereof for protecting buildings from seismic damage can make further improvements on isolation performance. The control forces in active controllers of hybrid isolation systems are analyzed and the damping characteristics of control forces in active controllers are then observed. Two indices are defined to quantify the damping characteristics of control force in active controllers. Based on the observation of damping characteristics of control forces in active controllers, a design approach for semi-active, smart and even passive dampers in a hybrid isolation system is presented. For comparative design purposes, the average value of maximum control forces in active controllers and control devices to be designed for several excitation records are assumed to be the same, i.e. the control design is normalization. A five-storey building and the smart base-isolated benchmark building are employed as numerical studies. The simulation results demonstrate that smart base isolation systems designed by using the proposed design approach can achieve almost the same performance as an active base isolation system in protecting the safety of buildings against strong earthquakes. Additionally, active controllers or semi-active controllers in hybrid base isolation system present the behavior of passive devices. And thus passive devices in base isolation systems can be instead of active controllers or semi-active controllers with the performance of the base isolation system remaining. Copyright © 2005 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.104

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Li, H., & Ou, J.
Venue
Structural Control and Health Monitoring
Published
2006
Volume
13
Issue
2-3
Pages
660-681
ISSN
  • 1545-2255 (ISSN-L)
  • 1545-2263
OpenAlex
W2003012691
Cited by
47
References
0
FWCI
6.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.