SMC structural health monitoring benchmark problem using monitored data from an actual cable-stayed bridge

Li, Shunlong, Li, Hui, Liu, Yang, Lan, Chengming, Zhou, Wensong, Ou, Jinping·2014·Structural Control and Health Monitoring

Abstract

A structural health monitoring (SHM) system provides an efficient way to diagnose the condition of critical and large-scale structures such as long-span bridges. With the development of SHM techniques, numerous condition assessment and damage diagnosis methods have been developed to monitor the evolution of deterioration and long-term structural performance of such structures, as well as to conduct rapid damage and post-disaster assessments. However, the condition assessment and the damage detection methods described in the literature are usually validated by numerical simulation and/or laboratory testing of small-scale structures with assumed deterioration models and artificial damage, which makes the comparison of different methods invalid and unconvincing to a certain extent. This paper presents a full-scale bridge benchmark problem organized by the Center of Structural Monitoring and Control at the Harbin Institute of Technology. The benchmark bridge structure, the SHM system, the finite element model of the bridge, and the monitored data are presented in detail. Focusing on two critical and vulnerable components of cable-stayed bridges, two benchmark problems are proposed on the basis of the field monitoring data from the full-scale bridge, that is, condition assessment of stay cables (Benchmark Problem 1) and damage detection of bridge girders (Benchmark Problem 2). For Benchmark Problem 1, the monitored cable stresses and the fatigue properties of the deteriorated steel wires and cables are presented. The fatigue life prediction model and the residual fatigue life assessment of the cables are the foci of this problem. For Benchmark Problem 2, several damage patterns were observed for the cable-stayed bridge. The acceleration time histories, together with the environmental conditions during the damage development process of the bridge, are provided. Researchers are encouraged to detect and to localize the damage and the damage development process. All the datasets and detailed descriptions, including the cable stresses, the acceleration datasets, and the finite element model, are available on the Structural Monitoring and Control website (http://smc.hit.edu.cn). Copyright © 2013 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.1559

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 180

Metadata

Authors
Li, S., Li, H., Liu, Y., Lan, C., Zhou, W., & Ou, J.
Venue
Structural Control and Health Monitoring
Published
2013-03-26
Volume
21
Issue
2
Pages
156-172
ISSN
1545-2255 (ISSN-L)
OpenAlex
W2132112746
Cited by
180
References
3
FWCI
16.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SMC structural health monitoring benchmark problem using monitored data from an actual cable-stayed bridge. https://app.cochat.ai/papers/10.1002/stc.1559
The paper
Li, S., Li, H., Liu, Y., Lan, C., Zhou, W., & Ou, J. (2014). SMC structural health monitoring benchmark problem using monitored data from an actual cable-stayed bridge. Structural Control and Health Monitoring. https://doi.org/10.1002/stc.1559

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.