A closed-form optimal tuning criterion for TMD in damped structures
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The selection of optimum absorber parameters is of utmost importance in the case of vibration control by the tuned mass damper (TMD). This paper presents an alternative expression for the optimum tuning ratio of the TMD. It has been derived in closed-form, based on the ‘fixed-point’ theory of Den Hartog which had been proposed for the case of undamped structural systems. The present expression has the advantage of being applicable for damped structures. The values of the optimum tuning ratio have been derived from the expression proposed in this paper for different structural and damper parameters. These values of optimum tuning ratio have been compared with those obtained from existing theories as well as from those obtained numerically. A simulation study has also been carried out to examine the performance of the optimally designed TMD. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Note on the Damped Vibration Absorber
Brock, J. E. (1946) · Journal of Applied Mechanics · doi:10.1115/1.4009588 · Cited by 356
Design formulas for tuned mass dampers based on a perturbation technique
Fujino, Y., & Abé, M. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290221002 · Cited by 276 · cited 2×
“Fujino and Abe [7] have employed a perturbation technique to derive formulas for optimal TMD parameters which may be used with good accuracy for mass ratios less than 0.”
MethodInfluential
Cited by
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Performance evaluation for inerter-based dynamic vibration absorbers
Hu, Y., & Chen, M. Z. Q. (2015) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2015.06.003 · Cited by 325
Structural control and vibration issues in wind turbines: A review
Xie, F., & Aly, A.-M. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2019.110087 · Cited by 159
Zhang, Z., Staino, A., Basu, B., & Nielsen, S. R. K. (2016) · Engineering Structures · doi:10.1016/j.engstruct.2016.07.008 · Cited by 150
Self-citationTuned mass-damper-inerter (TMDI) for suppressing edgewise vibrations of wind turbine blades
Zhang, Z., & Fitzgerald, B. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2020.110928 · Cited by 132
Robust design optimization of TMDs in vehicle–bridge coupled vibration problems
Miguel, L. F. F., Lopez, R. H., Torii, A. J., Miguel, L. F. F., & Beck, A. T. (2016) · Engineering Structures · doi:10.1016/j.engstruct.2016.08.033 · Cited by 104
Miguel, L. F. F., Fadel Miguel, L. F., & Lopez, R. H. (2015) · Optimization and Engineering · doi:10.1007/s11081-014-9269-3 · Cited by 52
Metadata
- Authors
- Ghosh, A., & Basu, B.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Hindawi Limited
- Published
- 2007
- Volume
- 14
- Issue
- 4
- Pages
- 681-692
- ISSN
- 1545-2255 (ISSN-L)
- 1545-2263
- OpenAlex
- W2049529822
- Cited by
- 170
- References
- 2
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.