An adaptive‐passive retuning device for a pendulum tuned mass damper considering mass uncertainty and optimum frequency
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
A tuned mass damper (TMD) is one of the most used structural control devices. However, a traditional TMD has the disadvantage of high sensitivity to frequency deviation and difficulty adjusting the frequency. The optimal frequency for a TMD is dependent on the structural dominant frequency and the TMD mass ratio. Nevertheless, the actual structural modal mass is difficult to obtain, and the presence of a TMD may interfere with identification of the natural structural frequency. Aiming to control wind-induced vibration, an adaptive-passive retuning device is developed for a pendulum TMD called an adaptive-passive variable pendulum TMD (APVP-TMD). When it is time to adjust the pendulum, the mass will first be locked, and the structural frequency in this case is identified through wavelet transformation by an acceleration sensor and a microcontroller. It is found that this is actually the optimal frequency for the TMD. Then, a stepper motor will adjust the length of the pendulum under the guidance of the microcontroller. The effectiveness of APVP-TMD is verified through both discrete and continuous models. For the discrete model, a single-degree-of-freedom primary structure coupled with an APVP-TMD is presented as an experiment with analysis comparison, and a five-degree-of-freedom primary structure coupled with an APVP-TMD is proposed as a numerical simulation. For the continuous model, a wind-sensitive concrete chimney is controlled by an APVP-TMD as a case study. The results all show that the APVP-TMD can identify the optimal frequency and retune itself effectively, and the retuned TMD has better vibration control than the mistuned one.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BISHOP, R. E. D. (1957) · Nature · doi:10.1038/179504a0 · Cited by 1,636
Bi-directional vibration control of offshore wind turbines using a 3D pendulum tuned mass damper
Sun, C., & Jahangiri, V. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2017.12.011 · Cited by 262
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
Nagarajaiah, S., & Varadarajan, N. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2004.10.015 · Cited by 212
Dinh, V.-N., & Basu, B. (2015) · Structural Control and Health Monitoring · doi:10.1002/stc.1666 · Cited by 204
Nagarajaiah, S., & Basu, B. (2009) · Earthquake Engineering and Engineering Vibration · doi:10.1007/s11803-009-9120-6 · Cited by 201
Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers
Nagarajaiah, S., & Sonmez, E. (2007) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2007)133:1(67 · Cited by 190
Varadarajan, N., & Nagarajaiah, S. (2004) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(2004)130:4(451 · Cited by 172
Control of flapwise vibrations in wind turbine blades using semi-active tuned mass dampers
Arrigan, J., Pakrashi, V., Basu, B., & Nagarajaiah, S. (2011) · Structural Control and Health Monitoring · doi:10.1002/stc.404 · Cited by 168
Semi-active control of monopile offshore wind turbines under multi-hazards
Sun, C. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2017.06.016 · Cited by 160
Cited by
Experimental Measurements of Wind Flow Characteristics on an Ellipsoidal Vertical Farm
Xie, S., Martinez-Vazquez, P., & Baniotopoulos, C. (2024) · Buildings · doi:10.3390/buildings14113646 · Cited by 6
Metadata
- Authors
- Wang, L., Shi, W., Li, X., Zhang, Q., & Zhou, Y.
- Venue
- Structural Control and Health Monitoring
- Publisher
- Wiley
- Published
- 2019-05-22
- Volume
- 26
- Issue
- 7
- Pages
- e2377
- ISSN
- 1545-2255 (ISSN-L)
- 1545-2263
- OpenAlex
- W2945105549
- Cited by
- 168
- References
- 41
- FWCI
- 8.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.