The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers
Abstract
This paper proposes application of single and multiple semiactive variable stiffness tuned mass dampers (STMD/SMTMD) for response control of multistory structures under several types of excitation. A new semiactive control algorithm is developed based on real-time frequency tracking of excitation signal by short time Fourier transform. A parametric study is performed in the frequency domain to investigate the dynamic characteristics and effectiveness of STMDs. Time history responses of single-degree-of-freedom and five-degree-of-freedom structures equipped with STMDs at the roof level, subjected to harmonic, stationary, and nonstationary excitations are presented. STMD/SMTMD are most effective when they have low damping ratios and the excitation frequency can be tracked. They are superior than their passive counterparts in reducing the response of the main structure both under force and base excitations. In case the fundamental frequency changes due to damage or deterioration of the main structure then the TMD will be off-tune; hence, it will lose its effectiveness significantly, whereas, the STMD is robust against such changes as it is always tuned to the excitation frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yamaguchi, H., & Harnpornchai, N. (1993) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.4290220105 · Cited by 341
Performance of Multiple Mass Dampers under Random Loading
Kareem, A., & Kline, S. (1995) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1995)121:2(348) · Cited by 306
Cited by
Bi-directional vibration control of offshore wind turbines using a 3D pendulum tuned mass damper
Sun, C., & Jahangiri, V. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2017.12.011 · Cited by 262
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
Self-citationSemi-active vibration absorber based on real-time controlled MR damper
Weber, F. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.017 · Cited by 180
Vibration mitigation in offshore wind turbines via tuned mass damper
Ghassempour, M., Failla, G., & Arena, F. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2018.12.092 · Cited by 124
Yang, D.-H., Shin, J.-H., Lee, H., Kim, S.-K., & Kwak, M. K. (2017) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.12.036 · Cited by 107
Metadata
- Authors
- Nagarajaiah, S., & Sonmez, E.
- Venue
- Journal of Structural Engineering
- Published
- 2007-01
- Volume
- 133
- Issue
- 1
- Pages
- 67-77
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- DOI
- 10.1061/(asce)0733-9445(2007)133:1(67
- OpenAlex
- W1985675087
- Cited by
- 190
- References
- 2
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers. https://app.cochat.ai/papers/10.1061/(asce)0733-9445(2007)133:1(67
- The paper
- Nagarajaiah, S., & Sonmez, E. (2007). Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers. Journal of Structural Engineering. https://doi.org/10.1061/(asce)0733-9445(2007)133%3A1(67
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.