CoChat

Two-stage optimum design of tuned mass dampers with consideration of stroke

Open access
Wang, Jer-Fu, Lin, Chi-Chang, Lian, Chien-Hsun · 2009 · Structural Control and Health Monitoring
Cited by 60

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This paper presents a two-stage optimum design procedure for passive tuned mass dampers (PTMDs) to reduce structural dynamic responses with the limitation of PTMD stroke. A new performance index, with the linear combination of structural response ratio and PTMD stroke ratio by a weighting factor α, is proposed. α ranges from 0 to 1.0. The larger the α, the more important the consideration of the stroke. When α equals 1.0, the PTMD is locked. The analytical results show that with little sacrifice of structural control effectiveness, the PTMD stroke can be significantly suppressed when an appropriate α is selected. The numerical simulation of a three-story building under earthquake excitations demonstrated that the proposed optimum PTMD performs as well as the conventional PTMD and its stroke is 30% reduced. Based on the analysis results, it is proved that the new optimum design concept is more flexible and useful in practical application. Copyright © 2009 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/stc.312

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Wang, J.-F., Lin, C.-C., & Lian, C.-H.
Venue
Structural Control and Health Monitoring
Published
2009-02
Volume
16
Issue
1
Pages
55-72
ISSN
  • 1545-2255 (ISSN-L)
  • 1545-2263
OpenAlex
W1974668194
Cited by
60
References
5
FWCI
11.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.