The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Differentiation of Neural Progenitor Cells in a Microfluidic Chip-Generated Cytokine Gradient
Open accessAbstract
In early embryonic development, spatial gradients of diffusible signaling molecules play important roles in controlling differentiation of cell types or arrays in diverse tissues. Thus, the concentration of exogenous cytokines or growth factors at any given time is crucial to the formation of an enriched population of a desired cell type from primitive stem cells in vitro. Microfluidic technology has proven very useful in the creation of cell-friendly microenvironments. Such techniques are, however, currently limited to a few cell types. Improved versatility is required if these systems are to become practically applicable to stem cells showing various plasticity ranges. Here, we built a microfluidic platform in which cells can be exposed to stable concentration gradients of various signaling molecules for more than a week with only minimal handling and no external power source. To maintain stability of the gradient concentration, the osmotic pumping performance was optimized by balancing the capillary action and hydraulic pressure in the inlet reagent reservoirs. We cultured an enriched population of neural progenitors derived from human embryonic stem cells in our microfluidic chamber for 8 days under continuous cytokine gradients (sonic hedgehog, fibroblast growth factor 8, and bone morphogenetic protein 4). Neural progenitors successfully differentiated into neurons, generating a complex neural network. The average numbers of both neuronal cell body clusters and neurite bundles were directly proportional to sonic hedgehog concentrations in the gradient chip. The system was shown to be useful for both basic and translational research, with straightforward mechanisms and operational schemes. Disclosure of potential conflicts of interest is found at the end of this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A microfluidic multi-injector for gradient generation
Chung, B. G., Lin, F., & Jeon, N. L. (2006) · Lab on a Chip · doi:10.1039/b512667c · Cited by 104
Cited by
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Self-citationPark, J., Lee, B. K., Jeong, G. S., Hyun, J. K., Lee, C. J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c4lc00962b · Cited by 350
Self-citationIndustrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Lee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Self-citationDevelopment-on-chip: in vitro neural tube patterning with a microfluidic device
Demers, C. J., Soundararajan, P., Chennampally, P., Cox, G. A., Briscoe, J., Collins, S. D., & Smith, R. L. (2016) · Development · doi:10.1242/dev.126847 · Cited by 149
Metadata
- Authors
- Park, J. Y., Kim, S.-K., Woo, D.-H., Lee, E.-J., Kim, J.-H., & Lee, S.-H.
- Venue
- Stem Cells
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-08-26
- Volume
- 27
- Issue
- 11
- Pages
- 2646-2654
- ISSN
- 1066-5099 (ISSN-L)
- 1549-4918
- OpenAlex
- W2043668209
- Cited by
- 177
- References
- 1
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.