CoChat

Characterization of extrastriatal D2 in vivo specific binding of [18F](N‐methyl)benperidol using PET

Open access
Eisenstein, Sarah A., Koller, Jon M., Piccirillo, Marilyn, Kim, Ana, Antenor‐Dorsey, Jo Ann V., Videen, Tom O., Snyder, Abraham Z., Karimi, Morvarid, Moerlein, Stephen M., Black, Kevin J., Perlmutter, Joel S., Hershey, Tamara · 2012 · Synapse
Cited by 44

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PET imaging studies of the role of the dopamine D2 receptor family in movement and neuropsychiatric disorders are limited by the use of radioligands that have near‐equal affinities for D2 and D3 receptor subtypes and are susceptible to competition with endogenous dopamine. By contrast, the radioligand [18 F]N‐methylbenperidol ([18 F]NMB) has high selectivity and affinity for the D2 receptor subtype (D2R) and is not sensitive to endogenous dopamine. Although [18 F]NMB has high binding levels in striatum, its utility for measuring D2R in extrastriatal regions is unknown. A composite MR‐PET image was constructed across 14 healthy adult participants representing average NMB uptake 60 to 120 min after [18 F]NMB injection. Regional peak radioactivity was identified using a peak‐finding algorithm. FreeSurfer and manual tracing identified a priori regions of interest (ROI) on each individual's MR image and tissue activity curves were extracted from coregistered PET images. [18 F]NMB binding potentials (BP ND s) were calculated using the Logan graphical method with cerebellum as reference region. In eight unique participants, extrastriatal BP ND estimates were compared between Logan graphical methods and a three‐compartment kinetic tracer model. Radioactivity and BP ND levels were highest in striatum, lower in extrastriatal subcortical regions, and lowest in cortical regions relative to cerebellum. Age negatively correlated with striatal BP ND s. BP ND estimates for extrastriatal ROIs were highly correlated across kinetic and graphical methods. Our findings indicate that PET with [18 F]NMB measures specific binding in extrastriatal regions, making it a viable radioligand to study extrastriatal D2R levels in healthy and diseased states. Synapse 66:770–780, 2012. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/syn.21566

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Eisenstein, S. A., Koller, J. M., Piccirillo, M., Kim, A., Antenor‐Dorsey, J. A. V., Videen, T. O., Snyder, A. Z., Karimi, M., Moerlein, S. M., Black, K. J., Perlmutter, J. S., & Hershey, T.
Venue
Synapse
Publisher
Wiley
Published
2012-05-15
Volume
66
Issue
9
Pages
770-780
ISSN
  • 0887-4476 (ISSN-L)
  • 1098-2396
OpenAlex
W2154067471
Cited by
44
References
3
FWCI
2.04
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.