Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 329

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Meta‐analysis of second‐trimester markers for trisomy 21

Open access
Agathokleous, M., Chaveeva, P., Poon, L. C. Y., Kosinski, P., Nicolaides, K. H.·2013·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: To summarize by meta‐analysis the accumulated data on the screening performance of second‐trimester sonographic markers for fetal trisomy 21. Methods: We conducted a literature search to identify studies between 1995 and September 2012 that provided data on the incidence of sonographic markers in trisomy 21 and euploid fetuses at 14–24 weeks' gestation. Weighted independent estimates of detection rate, false‐positive rate and positive and negative likelihood ratios (LR) of markers were calculated. Results: A total of 48 studies was included in the analysis. The pooled estimates of positive and negative LR were, respectively: 5.83 (95% CI, 5.02–6.77) and 0.80 (95% CI, 0.75–0.86) for intracardiac echogenic focus; 27.52 (95% CI, 13.61–55.68) and 0.94 (95% CI, 0.91–0.98) for ventriculomegaly; 23.30 (95% CI, 14.35–37.83) and 0.80 (95% CI, 0.74–0.85) for increased nuchal fold; 11.44 (95% CI, 9.05–14.47) and 0.90 (95% CI, 0.86–0.94) for hyperechogenic bowel; 7.63 (95% CI, 6.11–9.51) and 0.92 (95% CI, 0.89–0.96) for mild hydronephrosis; 3.72 (95% CI, 2.79–4.97) and 0.80 (95% CI, 0.73–0.88) for short femur; 4.81 (95% CI, 3.49–6.62) and 0.74 (95% CI, 0.63–0.88) for short humerus; 21.48 (95% CI, 11.48–40.19) and 0.71 (95% CI, 0.57–0.88) for aberrant right subclavian artery (ARSA); and 23.27 (95% CI, 14.23–38.06) and 0.46 (95% CI, 0.36–0.58) for absent or hypoplastic nasal bone. The combined negative LR, obtained by multiplying the values of individual markers, was 0.13 (95% CI, 0.05–0.29) when short femur but not short humerus was included and 0.12 (95% CI, 0.06–0.29) when short humerus but not short femur was included. Conclusion: The presence of sonographic markers increases, and absence of such markers decreases, the risk for trisomy 21. In the case of most isolated markers there is only a small effect on modifying the pre‐test odds for trisomy 21, but with ventriculomegaly, nuchal fold thickness and ARSA there is a 3–4‐fold increase in risk and with hypoplastic nasal bone a 6–7‐fold increase. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.12364

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 329

Metadata

Authors
Agathokleous, M., Chaveeva, P., Poon, L. C. Y., Kosinski, P., & Nicolaides, K. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2013-01-24
Volume
41
Issue
3
Pages
247-261
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1599865413
Cited by
329
References
1
FWCI
16.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Meta‐analysis of second‐trimester markers for trisomy 21. https://app.cochat.ai/papers/10.1002/uog.12364
The paper
Agathokleous, M., Chaveeva, P., Poon, L. C. Y., Kosinski, P., & Nicolaides, K. H. (2013). Meta‐analysis of second‐trimester markers for trisomy 21. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.12364

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.