Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 221

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Morbidly adherent placenta: evaluation of ultrasound diagnostic criteria and differentiation of placenta accreta from percreta

Calì, G., Giambanco, L., Puccio, G., Forlani, F. · 2013 · Ultrasound in Obstetrics & Gynecology

Abstract

Objectives: To evaluate the diagnostic accuracy of two‐dimensional (2D) gray‐scale and color Doppler and three‐dimensional (3D) power Doppler sonographic criteria for morbidly adherent placenta (MAP), and to identify criteria to help distinguish placenta accreta from placenta percreta. Methods: We enrolled 187 patients with placenta previa and history of uterine surgery and performed transabdominal and transvaginal ultrasound examination for early detection of MAP. With 2D gray‐scale transabdominal and transvaginal ultrasonography, we investigated loss/irregularity of the echolucent area between the uterus and the placenta (‘clear space’), thinning or interruption of the hyperechoic interface between the uterine serosa and the bladder wall and the presence of turbulent placental lacunae with high‐velocity flow (>15 cm/s). Using transabdominal 3D power Doppler, we evaluated the hypervascularity of the uterine serosa–bladder wall interface and irregular intraplacental vascularization. Ultrasound findings were reviewed against the final diagnosis made during Cesarean section (CS). Results: MAP was detected on CS in 41 patients. All of them had an anterior placenta previa (34 major and seven minor) and had undergone at least one previous CS. The evaluated sonographic criteria showed good diagnostic performance; in MAP patients at least two out of five criteria were detected, with at most one of the criteria present in patients without MAP. Loss/irregularity of clear space used as a single criterion was responsible for the most false positives, demonstrating a low positive predictive value. Irregular intraplacental vascularization with tortuous confluent vessels affecting the entire width of the placenta, and hypervascularity of the entire uterine serosa–bladder wall interface, were only detected, on 3D power Doppler, in cases of placenta percreta. Conclusions: The reviewed ultrasound criteria may be useful for the prenatal diagnosis of MAP and to differentiate between placenta accreta and placenta percreta; 3D power Doppler techniques were an important aid in the diagnosis. Copyright © 2013 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.12385

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 35

  1. 10.1080/00016340601088448 · DOI
  2. 10.1016/j.placenta.2006.06.011 · DOI
  3. 10.1016/S0002-9378(97)70463-0 · DOI · Paper page
  4. Clark SL, 1985, Placenta previa/accreta and prior caesarean section, Obstet Gynecol, 66, 89
  5. 10.1002/uog.8827 · DOI
  6. 10.1053/plac.2001.0764 · DOI · Paper page
  7. 10.1111/j.1600-0412.2011.01147.x · DOI · Paper page
  8. 10.1002/jcu.20524 · DOI
  9. 10.2214/AJR.11.6858 · DOI
  10. 10.1097/01.AOG.0000233155.62906.6d · DOI · Paper page
  11. 10.1016/j.mri.2006.10.007 · DOI · Paper page
  12. Thorp JM, 1992, Antepartum diagnosis of placenta previa percreta by magnetic resonance imaging, Obstet Gynecol, 80, 506
  13. 10.1515/jpme.1993.21.2.165 · doi:10.1515/jpme.1993.21.2.165
  14. 10.1067/mob.2001.115282 · DOI
  15. 10.1002/uog.6284 · DOI · Paper page
  16. 10.1016/0002-9378(90)91056-I · DOI
  17. 10.1046/j.1469-0705.1995.05030198.x · DOI
  18. 10.1097/GCO.0b013e328342b730 · DOI
  19. 10.1111/j.1479-828X.2011.01400.x · DOI
  20. 10.7863/jum.2008.27.11.1623 · DOI
  21. 10.1038/sj.jp.7211442 · DOI
  22. 10.1097/01.AOG.0000149156.07061.1f · DOI · Paper page
  23. 10.7863/jum.1992.11.7.333 · DOI · Paper page
  24. 10.1002/uog.2797 · DOI
  25. 10.1016/S1028-4559(09)60033-4 · DOI
  26. 10.1046/j.1469-0705.2002.00731_2.x · DOI
  27. 10.1016/j.contraception.2011.08.011 · DOI
  28. Royal College of Obstetricians and Gynaecologists, Placenta praevia, placenta praevia accreta and vasa praevia: diagnosis and management
  29. 10.1111/j.1471-0528.1996.tb09903.x · DOI
  30. 10.1111/j.1471-0528.2008.02037.x · DOI · Paper page
  31. 10.1111/j.1447-0756.1996.tb00953.x · DOI
  32. Imseis HM, 1998, Spontaneous rupture of a primigravid uterus secondary to placenta percreta. A case report, J Reprod Med, 43, 233
  33. Baloul SM, 2002, Placenta percreta with painless uterine rupture at the second trimester, Saudi Med J, 23, 857
  34. 10.1016/j.ajog.2012.03.007 · DOI · Paper page
  35. 10.1111/j.0001-6349.2005.00832.x · doi:10.1111/j.0001-6349.2005.00832.x · Paper page

Cited by

See all 221

Metadata

Authors
Calì, G., Giambanco, L., Puccio, G., & Forlani, F.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2013-03-25
Volume
41
Issue
4
Pages
406-412
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W1778177045
Cited by
221
References
5
FWCI
14.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morbidly adherent placenta: evaluation of ultrasound diagnostic criteria and differentiation of placenta accreta from percreta. https://app.cochat.ai/papers/10.1002/uog.12385
The paper
Calì, G., Giambanco, L., Puccio, G., & Forlani, F. (2013). Morbidly adherent placenta: evaluation of ultrasound diagnostic criteria and differentiation of placenta accreta from percreta. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.12385

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.