Neurodevelopmental outcome of full‐term small‐for‐gestational‐age infants with normal placental function
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Objective: To evaluate the 2‐year neurodevelopmental outcome of full‐term, small‐for‐gestational‐age (SGA) newborns with normal placental function, according to current criteria based on umbilical artery Doppler findings. Methods: A cohort of consecutive full‐term, SGA newborns with normal prenatal umbilical artery Doppler was compared with a group of full‐term, appropriate‐for‐gestational‐age (AGA) infants sampled from our general neonatal population. Neurodevelopmental outcome was evaluated at 24 months' corrected age using the Bayley Scales of Infant and Toddler Development, 3 rd Edition (Bayley‐III), which evaluates cognitive, language, motor, social‐emotional and adaptive competencies. The effect of the study group on each domain was adjusted with MANCOVA and logistic regression for gestational age at delivery, socioeconomic status, gender, tobacco smoking and breastfeeding. Results: A total of 223 infants (112 SGA and 111 AGA) were included. The groups differed significantly with respect to socioeconomic status and gestational age at delivery. All studied neurodevelopmental domains were poorer in the SGA group, reaching significance for the cognitive (92.9 vs 100.2, adjusted P = 0.027), language (94.7 vs 101, adjusted P = 0.025), motor (94.2 vs 100, adjusted P = 0.027) and adaptive (89.2 vs 96.5, adjusted P = 0.012) scores. Likewise, the SGA group had a higher risk of low scores in language (odds ratio (OR) = 2.63; adjusted P = 0.045) and adaptive (OR = 2.72; adjusted P = 0.009) domains. Conclusions: Compared with normal‐sized babies, full‐term SGA infants, without placental insufficiency defined according to currently used criteria, have lower 2‐year neurodevelopmental scores. These data challenge the concept that SGA fetuses with normal umbilical artery Doppler are ‘constitutionally small’ but otherwise completely normal. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term neurodevelopmental outcomes after intrauterine and neonatal insults: a systematic review
Mwaniki, M. K., Atieno, M., Lawn, J. E., & Newton, C. R. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61577-8 · Cited by 860
Long-Term Effects of Early Childhood Programs on Social Outcomes and Delinquency
Yoshikawa, H. (1995) · The Future of Children · doi:10.2307/1602367 · Cited by 451
Leitner, Y., Fattal-Valevski, A., Geva, R., Eshel, R., Toledano-Alhadef, H., Rotstein, M., Bassan, H., Radianu, B., Bitchonsky, O., Jaffa, A. J., et al. (2007) · Journal of Child Neurology · doi:10.1177/0883073807302605 · Cited by 332
Effect of placental embolization on the umbilical arterial velocity waveform in fetal sheep
Morrow, R. J., Adamson, S. L., Bull, S. B., & Knox Ritchie, J. W. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90783-7 · Cited by 243
Feldman, R., & Eidelman, A. I. (2006) · PEDIATRICS · doi:10.1542/peds.2005-2040 · Cited by 196
Savchev, S., Figueras, F., Cruz‐Martinez, R., Illa, M., Botet, F., & Gratacos, E. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10150 · Cited by 160
Self-citationFigueras, F., Eixarch, E., Meler, E., Iraola, A., Figueras, J., Puerto, B., & Gratacos, E. (2008) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2007.02.016 · Cited by 121
Self-citationMathematical model for interpretation of Doppler velocity waveform indices
Thompson, R. S., & Stevens, R. J. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441484 · Cited by 71
Cited by
Melamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Self-citationMcCowan, L. M., Figueras, F., & Anderson, N. H. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.004 · Cited by 451
Self-citationSacchi, C., Marino, C., Nosarti, C., Vieno, A., Visentin, S., & Simonelli, A. (2020) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2020.1097 · Cited by 374
Feig, D. S., Donovan, L. E., Zinman, B., Sanchez, J. J., Asztalos, E., Ryan, E. A., Fantus, I. G., Hutton, E., Armson, A. B., Lipscombe, L. L., et al. (2020) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(20)30310-7 · Cited by 234
Savchev, S., Figueras, F., Sanz-Cortes, M., Cruz-Lemini, M., Triunfo, S., Botet, F., & Gratacos, E. (2014) · Fetal Diagnosis and Therapy · doi:10.1159/000355525 · Cited by 182
Self-citation
Metadata
- Authors
- Savchev, S., Sanz‐Cortes, M., Cruz‐Martinez, R., Arranz, A., Botet, F., Gratacos, E., & Figueras, F.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2013-06-27
- Volume
- 42
- Issue
- 2
- Pages
- 201-206
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1731603392
- Cited by
- 151
- References
- 8
- FWCI
- 9.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.