The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Non‐invasive prenatal testing for fetal chromosomal abnormalities by low‐coverage whole‐genome sequencing of maternal plasma DNA: review of 1982 consecutive cases in a single center
Open accessAbstract
Objective: To review the performance of non‐invasive prenatal testing (NIPT) by low‐coverage whole‐genome sequencing of maternal plasma DNA at a single center. Methods: The NIPT result and pregnancy outcome of 1982 consecutive cases were reviewed. NIPT was based on low coverage (0.1×) whole‐genome sequencing of maternal plasma DNA. All subjects were contacted for pregnancy and fetal outcome. Results: Of the 1982 NIPT tests, a repeat blood sample was required in 23 (1.16%). In one case, a conclusive report could not be issued, probably because of an abnormal vanished twin fetus. NIPT was positive for common trisomies in 29 cases (23 were trisomy 21, four were trisomy 18 and two were trisomy 13); all were confirmed by prenatal karyotyping (specificity = 100%). In addition, 11 cases were positive for sex‐chromosomal abnormalities (SCA), and nine cases were positive for other aneuploidies or deletion/duplication. Fourteen of these 20 subjects agreed to undergo further investigations, and the abnormality was found to be of fetal origin in seven, confined placental mosaicism (CPM) in four, of maternal origin in two and not confirmed in one. Overall, 85.7% of the NIPT‐suspected SCA were of fetal origin, and 66.7% of the other abnormalities were caused by CPM. Two of the six cases suspected or confirmed to have CPM were complicated by early‐onset growth restriction requiring delivery before 34 weeks. Fetal outcome of the NIPT‐negative cases was ascertained in 1645 (85.15%). Three chromosomal abnormalities were not detected by NIPT, including one case each of a balanced translocation, unbalanced translocation and triploidy. There were no known false negatives involving the common trisomies (sensitivity = 100%). Conclusions: Low‐coverage whole‐genome sequencing of maternal plasma DNA was highly accurate in detecting common trisomies. It also enabled the detection of other aneuploidies and structural chromosomal abnormalities with high positive predictive value. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nuchal translucency and other first-trimester sonographic markers of chromosomal abnormalities
Nicolaides, K. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.090 · Cited by 626
Jeon, K. C., Chen, L.-S., & Goodson, P. (2012) · Genetics in Medicine · doi:10.1038/gim.0b013e31822e57a7 · Cited by 139
Cited by
Gil, M. M., Quezada, M. S., Revello, R., Akolekar, R., & Nicolaides, K. H. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14791 · Cited by 807
Taylor-Phillips, S., Freeman, K., Geppert, J., Agbebiyi, A., Uthman, O. A., Madan, J., Clarke, A., Quenby, S., & Clarke, A. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010002 · Cited by 410
Zhang, H., Gao, Y., Jiang, F., Fu, M., Yuan, Y., Guo, Y., Zhu, Z., Lin, M., Liu, Q., Tian, Z., et al. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14792 · Cited by 389
Self-citation
Metadata
- Authors
- Lau, T. K., Cheung, S. W., Lo, P. S. S., Pursley, A. N., Chan, M. K., Jiang, F., Zhang, H., Wang, W., Jong, L. F. J., Yuen, O. K. C., Chan, H. Y. C., Chan, W. S. K., & Choy, K. W.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2014-02-10
- Volume
- 43
- Issue
- 3
- Pages
- 254-264
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2099650901
- Cited by
- 160
- References
- 2
- FWCI
- 17.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.