Systematic review of accuracy of ultrasound in the diagnosis of vasa previa
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective: Vasa previa is an obstetric complication in which the fetal blood vessels lie outside the chorionic plate in close proximity to the internal cervical os. In women with vasa previa, the risk of rupture of these vessels is increased, thus potentially causing fetal death or serious morbidity. Our objective was to assess the accuracy of ultrasound in the prenatal diagnosis of vasa previa. Methods: We searched MEDLINE, EMBASE, the Cochrane Library and PubMed for studies on vasa previa. Two reviewers independently selected studies on the accuracy of ultrasound in the diagnosis of vasa previa. The studies were scored on methodological quality using the Quality Assessment of Diagnostic Accuracy Studies tool (QUADAS‐2). Data on sensitivity and specificity were subsequently extracted. Results: The literature search revealed 583 articles, of which two prospective and six retrospective cohort studies were eligible for inclusion in the qualitative analysis. All studies documented methods suitable for the prenatal diagnosis of vasa previa. Four out of the eight studies used transvaginal ultrasound (TVS) for primary evaluation, while the remaining four studies used transabdominal ultrasound and performed a subsequent TVS when vasa previa was suspected. The QUADAS‐2 tool reflected poor methodology in six of the eight included studies, and prenatal detection rates varied from 53% (10/19) to 100% (total of 442 633 patients, including 138 cases of vasa previa). In the two prospective studies (n = 33 795, including 11 cases of vasa previa), transvaginal color Doppler performed during the second trimester detected all cases of vasa previa (sensitivity, 100%) with a specificity of 99.0–99.8%. Conclusion: The accuracy of ultrasound in the diagnosis of vasa previa is high when performed transvaginally in combination with color Doppler. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Prediction of risk for vasa previa at 9–13 weeks’ gestation
Hasegawa, J., Nakamura, M., Sekizawa, A., Matsuoka, R., Ichizuka, K., & Okai, T. (2011) · Journal of Obstetrics and Gynaecology Research · doi:10.1111/j.1447-0756.2011.01525.x · Cited by 41
Cited by
(2018) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14831 · Cited by 216
“Color and pulsed Doppler ultrasound should be used to assess vasa previa or abnormal placental cord insertion.(75)”
MethodIncidence of and risk indicators for vasa praevia: a systematic review
Ruiter, L., Kok, N., Limpens, J., Derks, J., de Graaf, I., Mol, B., & Pajkrt, E. (2016) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13829 · Cited by 141
Self-citationVasa Praevia: Diagnosis and Management: Green‐top Guideline No. 27b
Jauniaux, E., Alfirevic, Z., Bhide, A., Burton, G., Collins, S., Silver, R., & the Royal College of Obstetricians and Gynaecologists (2019) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.15307 · Cited by 88
Metadata
- Authors
- Ruiter, L., Kok, N., Limpens, J., Derks, J. B., de Graaf, I. M., Mol, B. W. J., & Pajkrt, E.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2015-04-13
- Volume
- 45
- Issue
- 5
- Pages
- 516-522
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1537246158
- Cited by
- 124
- References
- 4
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic review of accuracy of ultrasound in the diagnosis of vasa previa. https://app.cochat.ai/papers/10.1002/uog.14752
- The paper
- Ruiter, L., Kok, N., Limpens, J., Derks, J. B., de Graaf, I. M., Mol, B. W. J., & Pajkrt, E. (2015). Systematic review of accuracy of ultrasound in the diagnosis of vasa previa. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.14752
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.