CoChat

Estimating risk of malignancy in adnexal masses: external validation of the ADNEX model and comparison with other frequently used ultrasound methods

Open access
Meys, E. M. J., Jeelof, L. S., Achten, N. M. J., Slangen, B. F. M., Lambrechts, S., Kruitwagen, R. F. P. M., Van Gorp, T. · 2017 · Ultrasound in Obstetrics & Gynecology
Cited by 108

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objectives: To validate externally the performance of the Assessment of Different NEoplasias in the adneXa (ADNEX) model and compare this model with other frequently used models in the differentiation between benign and malignant adnexal masses. Methods: In this retrospective diagnostic accuracy study, we assessed data collected prospectively from patients with adnexal pathology who underwent real‐time transvaginal or transrectal ultrasound by a single expert ultrasonographer in a tertiary care hospital between July 2011 and July 2015. The presence of a malignancy was determined by subjective assessment and use of four prediction models: the ADNEX model, simple ultrasound‐based rules (simple rules), Logistic Regression model 2 (LR2) and the Risk of Malignancy Index (RMI), of which three different variants were assessed. Pathology was the clinical reference standard. Results: In total, 851 consecutive patients underwent ultrasound examination for an adnexal mass. For 326 patients (128 premenopausal and 198 postmenopausal), pathology results were available (211 (64.7%) benign; 115 (35.3%) malignant) and these were included in the analysis. The area under the receiver–operating characteristics curve (AUC) of the ADNEX model for the discrimination between benign and malignant tumors was 0.93 (95% CI, 0.89–0.95). AUCs for the subtypes of malignancy (i.e. borderline, Stage I–IV and metastatic adnexal tumors) ranged between 0.60 and 0.90. Only subjective assessment (AUC, 0.96 (95% CI, 0.93–0.98)) was superior to the ADNEX model (P = 0.01) in differentiating malignant from benign tumors. AUCs for the other models were 0.92 (95% CI, 0.89–0.95) for LR2, 0.85 (95% CI, 0.81–0.89) for RMI‐I, 0.82 (95% CI, 0.77–0.86) for RMI‐II and 0.84 (95% CI, 0.80–0.88) for RMI‐III. At the proposed cut‐off of ≥ 10%, the ADNEX model had the highest sensitivity (0.98 (95% CI, 0.93–1.00)) but the lowest specificity (0.62 (95% CI, 0.55–0.68)) compared with the other models. Both subjective assessment (sensitivity, 0.90 (95% CI, 0.83–0.95); specificity 0.91 (95% CI, 0.86–0.94)) and the simple rules model with inconclusive cases classified by subjective assessment (sensitivity, 0.89 (95% CI, 0.81–0.94); specificity, 0.90 (95% CI, 0.85–0.94)) had lower sensitivity, but their sensitivity and specificity were better balanced. Conclusions: Although the test performance of subjective assessment by an expert remains superior, the ADNEX model can help in the differentiation between benign and malignant ovarian tumors. The advantage of the ADNEX model as a polytomous model remains to be shown. © 2016 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.17225

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 108

Metadata

Authors
Meys, E. M. J., Jeelof, L. S., Achten, N. M. J., Slangen, B. F. M., Lambrechts, S., Kruitwagen, R. F. P. M., & Van Gorp, T.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2017-06
Volume
49
Issue
6
Pages
784-792
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2510455894
Cited by
108
References
6
FWCI
5.99
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimating risk of malignancy in adnexal masses: external validation of the ADNEX model and comparison with other frequently used ultrasound methods. https://app.cochat.ai/papers/10.1002/uog.17225
The paper
Meys, E. M. J., Jeelof, L. S., Achten, N. M. J., Slangen, B. F. M., Lambrechts, S., Kruitwagen, R. F. P. M., & Van Gorp, T. (2017). Estimating risk of malignancy in adnexal masses: external validation of the ADNEX model and comparison with other frequently used ultrasound methods. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.17225

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.