CoChat

Population trends in prenatal detection of transposition of great arteries: impact of obstetric screening ultrasound guidelines

Open access
Ravi, P., Mills, L., Fruitman, D., Savard, W., Colen, T., Khoo, N., Serrano‐Lomelin, J., Hornberger, L. K. · 2018 · Ultrasound in Obstetrics & Gynecology
Cited by 51

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Objectives: Dextro‐transposition of the great arteries (d‐TGA) is one of the most common critical neonatal heart defects, with a low detection rate antenatally. We sought to evaluate trends in the prenatal detection of d‐TGA with or without ventricular septal defect (VSD) in Alberta over the past 13 years, examining the potential impact of ultrasound guidelines incorporating screening of cardiac outflow tracts, updated in 2009–2010 and in 2013, and factors affecting detection of the condition. Methods: All fetuses and neonates with d‐TGA, with or without VSD, encountered between 2003 and 2015 in the province of Alberta, were identified retrospectively. Clinical records including obstetric ultrasound reports were reviewed. Pregnancy outcome, common referral indications and associated maternal and fetal pathology in affected pregnancies were assessed. Results: From 2003 to 2015, 127 cases with d‐TGA were encountered in Alberta, of which 47 (37%) were detected prenatally. Prenatal detection improved over the study period, from 14% in 2003–2010, to 50% in 2011–2013, and to 77% in 2014–2015. Of the 47 fetuses with a prenatal diagnosis of d‐TGA, an indication for fetal echocardiography included abnormal or poorly visualized cardiac outflows with normal four‐chamber view in 46 (98%). Comorbidities were identified in 12 mothers, only five of which represented an additional reason for fetal echocardiography referral, and four fetuses had extracardiac pathology. Conclusion: Substantial improvement in the prenatal detection of d‐TGA has been observed in Alberta over the past few years, owing to improved screening of cardiac outflow tracts on routine obstetric ultrasound examination in otherwise healthy pregnancies, and has been temporally associated with updated obstetric ultrasound guidelines suggesting that these contributed to optimized screening of affected pregnancies. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.17496

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 51

Metadata

Authors
Ravi, P., Mills, L., Fruitman, D., Savard, W., Colen, T., Khoo, N., Serrano‐Lomelin, J., & Hornberger, L. K.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2018-05
Volume
51
Issue
5
Pages
659-664
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2608906533
Cited by
51
References
11
FWCI
2.60
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Population trends in prenatal detection of transposition of great arteries: impact of obstetric screening ultrasound guidelines. https://app.cochat.ai/papers/10.1002/uog.17496
The paper
Ravi, P., Mills, L., Fruitman, D., Savard, W., Colen, T., Khoo, N., Serrano‐Lomelin, J., & Hornberger, L. K. (2018). Population trends in prenatal detection of transposition of great arteries: impact of obstetric screening ultrasound guidelines. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.17496

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.