CoChat

The four‐chamber view: four reasons why it seems to fail in screening for cardiac abnormalities and suggestions to improve detection rate

Open access
Chaoui, R. · 2003 · Ultrasound in Obstetrics & Gynecology
Cited by 122

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The anticipated potential in the 1980s of the four-chamber view to detect 'most' or at least the severe cardiac anomalies was fulfilled in very few areas and centers, and widespread improvements in detection rates were not achieved. In my opinion, there are four possible reasons why the four-chamber view appears to fail. This editorial analyses these four reasons and attempts to suggest solutions to increase detection rates. Inadequate examination is likely to be the most common cause of heart defects being overlooked in the four-chamber view. The inadequately examined heart is frequently reported as normal, or as a 'limited examination due to fetal position', when the heart is examined at an inappropriate angle. The heart may not be examined in any greater detail than to observe cardiac rhythm. As the remainder of the fetus is screened properly (for example, with careful examination to exclude markers such as a banana sign for neural tube defect, chromosomal anomalies and complex malformations), the institution may have good detection rates for these anomalies, but may be less successful in the detection of fetal cardiac anomalies. Two major problems are commonly encountered: firstly, the examiner may not be able to obtain an adequate four-chamber view with different fetal positions and, secondly, the image is not optimized for the analysis of the heart. Other technical aspects also contribute to unsatisfactory visualization of the heart, even at specialized centers, and include: gestational age (20–23 weeks is preferable to 16–18 weeks1), transducer frequency (5 MHz is better than 3.5 MHz1) and objective fetal and maternal factors. DeVore et al.2 analyzed factors influencing imaging during the second trimester of pregnancy and found that even in expert hands the heart could not be properly imaged in 9% of cases due to maternal body habitus and previous abdominal surgery, and early gestational age, but very rarely because of fetal position. An additional reason for inadequate examination is 'lack of time'. In some units the whole fetal examination usually has to be achieved within a short time period (e.g. 15–20 min) due to the large number of patients being screened. Under these circumstances there may be no time to wait for the fetus to change its position or to change the different presets of the machine or use other transducers. Optimal analysis of the heart may be achieved by magnification of the image, using the zoom function (Figure 1), so that the heart fills a third to half of the screen, and by the use of the cine-loop to assess different phases of the cardiac cycle3. At institutions where regular problems with visualization of the heart arise, internal quality control may be useful. The Fetal Medicine Foundation has successfully demonstrated reproducible measurements in the range of a few millimeters in the assessment of nuchal translucency4. However, no such quality control exists for the examination of the fetal heart at this stage. Practical teaching with a hands-on approach for sonographers or perinatologists at specialized centers, followed by submission of a set of 50 images of a four-chamber view, for example, may lead to improvements in image quality. In Germany, in order to gain the qualification required to perform the examination, specialists in fetal echocardiography are required to submit a logbook of 100 images documenting appropriate cardiac examination. The introduction of a routine heart measurement (e.g. heart width or ventricular proportions) could be another approach to oblige the examiner to document the plane adequately during every examination. Appropriate teaching followed by quality control could be expected to lead to appropriate examination of the heart routinely. Four-chamber view at a non-optimal magnification (a) and after application of zoom function and magnification of the image (b). Details are better visualized on the magnified image. To improve visualization, the heart should ideally be examined between 20 and 22 weeks' gestation. A study from the Netherlands showed that integration of the four-chamber view into the standard examination at 15 centers achieved a detection rate for heart defects of only 4.5%: 44 heart anomalies were present within the group of 6922 fetuses examined, but only two were detected prenatally5. In comparison, Sharland and Allan6 have demonstrated that direct teaching can improve detection rates. In the south-east Thames region in the UK sonographers were trained not only to obtain but also to interpret the four-chamber view, and were able to detect 69% of all complex heart anomalies detectable in this plane. This study is supported by the results of Tegnander et al.7, who analyzed detection rates before and after introduction of a teaching program with the aim of obtaining the four-chamber view; detection rates increased from 18 to 39%. Further training in assessment of the great vessels increased detection rates to > 60% (Tegnander,

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.187

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Chaoui, R.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2003-07
Volume
22
Issue
1
Pages
3-10
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2031740814
Cited by
122
References
1
FWCI
4.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.