Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 385

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Comparison of diagnostic accuracy of early screening for pre‐eclampsia by NICE guidelines and a method combining maternal factors and biomarkers: results of SPREE

Open access
Tan, M. Y., Wright, D., Syngelaki, A., Akolekar, R., Cicero, S., Janga, D., Singh, M., Greco, E., Wright, A., Maclagan, K., Poon, L. C., Nicolaides, K. H.·2018·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: To test the hypothesis that the performance of first‐trimester screening for pre‐eclampsia (PE) by a method that uses Bayes' theorem to combine maternal factors with biomarkers is superior to that defined by current National Institute for Health and Care Excellence (NICE) guidelines. Methods: This was a prospective multicenter study (screening program for pre‐eclampsia (SPREE)) in seven National Health Service maternity hospitals in England, of women recruited between April and December 2016. Singleton pregnancies at 11–13 weeks' gestation had recording of maternal characteristics and medical history and measurements of mean arterial pressure (MAP), uterine artery pulsatility index (UtA‐PI), serum placental growth factor (PlGF) and serum pregnancy‐associated plasma protein‐A (PAPP‐A). The performance of screening for PE by the Bayes' theorem‐based method was compared with that of the NICE method. Primary comparison was detection rate (DR) using NICE method vs mini‐combined test (maternal factors, MAP and PAPP‐A) in the prediction of PE at any gestational age (all‐PE) for the same screen‐positive rate determined by the NICE method. Key secondary comparisons were DR of screening recommended by the NICE guidelines vs three Bayes' theorem‐based methods (maternal factors, MAP and PAPP‐A; maternal factors, MAP and PlGF; and maternal factors, MAP, UtA‐PI and PlGF) in the prediction of preterm PE, defined as that requiring delivery < 37 weeks. Results: All‐PE developed in 473 (2.8%) of the 16 747 pregnancies and preterm PE developed in 142 (0.8%). The screen‐positive rate by the NICE method was 10.3% and the DR for all‐PE was 30.4% and for preterm PE it was 40.8%. Compliance with the NICE recommendation that women at high risk for PE should be treated with aspirin from the first trimester to the end of pregnancy was only 23%. The DR of the mini‐combined test for all‐PE was 42.5%, which was superior to that of the NICE method by 12.1% (95% CI, 7.9–16.2%). In screening for preterm PE by a combination of maternal factors, MAP and PlGF, the DR was 69.0%, which was superior to that of the NICE method by 28.2% (95% CI, 19.4–37.0%) and with the addition of UtA‐PI the DR was 82.4%, which was higher than that of the NICE method by 41.6% (95% CI, 33.2–49.9%). Conclusions: The performance of screening for PE as currently recommended by NICE guidelines is poor and compliance with these guidelines is low. The performance of screening is substantially improved by a method combining maternal factors with biomarkers. © 2018 Crown copyright. Ultrasound in Obstetrics & Gynecology © 2018 ISUOG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.19039

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 385

Metadata

Authors
Tan, M. Y., Wright, D., Syngelaki, A., Akolekar, R., Cicero, S., Janga, D., Singh, M., Greco, E., Wright, A., Maclagan, K., Poon, L. C., & Nicolaides, K. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2018-03-14
Volume
51
Issue
6
Pages
743-750
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2790948098
Cited by
385
References
32
FWCI
33.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of diagnostic accuracy of early screening for pre‐eclampsia by NICE guidelines and a method combining maternal factors and biomarkers: results of SPREE. https://app.cochat.ai/papers/10.1002/uog.19039
The paper
Tan, M. Y., Wright, D., Syngelaki, A., Akolekar, R., Cicero, S., Janga, D., Singh, M., Greco, E., Wright, A., Maclagan, K., Poon, L. C., & Nicolaides, K. H. (2018). Comparison of diagnostic accuracy of early screening for pre‐eclampsia by NICE guidelines and a method combining maternal factors and biomarkers: results of SPREE. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.19039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.