Diagnostic accuracy of first‐trimester ultrasound in detecting abnormally invasive placenta in high‐risk women with placenta previa
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Objective: To ascertain the diagnostic accuracy of ultrasound in detecting abnormally invasive placenta (AIP) during the first trimester of pregnancy (11–14 weeks' gestation) in women at risk for this condition. Methods: This was a retrospective analysis of data collected prospectively from women at risk for AIP based upon the presence of at least one prior Cesarean section (CS) and/or uterine surgery and placenta previa, who had ultrasound assessment for AIP at the time of the 11–14‐week scan. The ultrasound signs explored in the present study were: loss of the clear zone, placental lacunae, bladder wall interruption and uterovesical hypervascularity. The potential of ultrasound and different ultrasound signs to predict the different types of AIP was assessed by computing summary estimates of sensitivity, specificity, diagnostic odds ratio (DOR) and positive (LR+) and negative (LR–) likelihood ratios. Results: One hundred and eighty‐eight women with placenta previa and at least one previous CS or uterine surgery were included in the study. All the explored ultrasound signs were associated significantly with the occurrence of AIP. Overall, when at least one ultrasound sign was used to make the diagnosis, ultrasound had a sensitivity of 84.3% (95% CI, 74.7–91.4%), specificity of 61.9% (95% CI, 51.9–71.2%), DOR of 8.6 (95% CI, 4.1–19.3), LR+ of 2.2 (95% CI, 1.7–2.9) and LR– of 0.3 (95% CI, 0.1–0.4) in detecting AIP. Using two ultrasound signs to label a case as positive increased the diagnostic accuracy in terms of specificity, although it did not affect sensitivity. Among the different ultrasound signs, loss of the clear zone had a sensitivity of 84.3% (95% CI, 74.7–91.4%) and a specificity of 81.9% (95% CI, 73.2–88.7%) in detecting AIP, while sensitivities for placental lacunae and bladder wall interruption were 78.3% (95% CI, 67.9–86.6%) and 75.9% (95% CI, 65.3–84.6%), respectively, and specificities were 81.0% (95% CI, 72.1–88.0%) and 99.1% (95% CI, 94.8–100.0%), respectively. The optimal combination of sensitivity and specificity was achieved when at least two imaging signs of AIP were used in the diagnostic algorithm. Conclusions: AIP can be detected from the first trimester of pregnancy in women at risk for this condition, and ultrasound performed between 11 and 14 weeks' gestation has an overall good diagnostic accuracy for detecting all types of AIP. However, these findings are applicable only to women with placenta previa and prior uterine scar. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration
Cohen, J. F., Korevaar, D. A., Altman, D. G., Bruns, D. E., Gatsonis, C. A., Hooft, L., Irwig, L., Levine, D., Reitsma, J. B., de Vet, H. C. W., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012799 · Cited by 2,570
Center of excellence for placenta accreta
Silver, R. M., Fox, K. A., Barton, J. R., Abuhamad, A. Z., Simhan, H., Huls, C. K., Belfort, M. A., & Wright, J. D. (2015) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2014.11.018 · Cited by 518
Belfort, M. A. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2010.09.013 · Cited by 484 · cited 1×
“The ultrasound signs explored in the present study (Figure 1) were7: (1) loss of the ‘clear zone’, defined as loss or irregularity of the hypoechoic plane in the myometrium beneath the placental bed; (2) placental lacunae, defined as the presence of numerous (at least three) lacunae, often containing turbulent flow vi…”
BackgroundD'Antonio, F., Iacovella, C., & Bhide, A. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13194 · Cited by 398
Self-citationProposal for standardized ultrasound descriptors of abnormally invasive placenta ( AIP )
Collins, S. L., Ashcroft, A., Braun, T., Calda, P., Langhoff‐Roos, J., Morel, O., Stefanovic, V., Tutschek, B., Chantraine, F., & on behalf of the European Working Group on Abnormally Invasive Placenta (EW‐AIP) (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14952 · Cited by 331
Morbidly Adherent Placenta Treatments and Outcomes
Bailit, J. L., Grobman, W. A., Rice, M. M., Reddy, U. M., Wapner, R. J., Varner, M. W., Leveno, K. J., Iams, J. D., Tita, A. T. N., Saade, G., et al. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000680 · Cited by 313
D'Antonio, F., Timor‐Tritsch, I. E., Palacios‐Jaraquemada, J., Monteagudo, A., Buca, D., Forlani, F., Minneci, G., Foti, F., Manzoli, L., Liberati, M., et al. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.18840 · Cited by 116
Self-citationTransvaginal ultrasonography in predicting placenta previa at delivery: a longitudinal study
Mustafá, S. A., Brizot, M. L., Carvalho, M. H. B., Watanabe, L., Kahhale, S., & Zugaib, M. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2002.00814.x · Cited by 77
Cited by
Tinari, S., Buca, D., Cali, G., Timor‐Tritsch, I., Palacios‐Jaraquemada, J., Rizzo, G., Lucidi, A., Di Mascio, D., Liberati, M., & D'Antonio, F. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22183 · Cited by 89
Self-citationPlacenta previa with posterior extrauterine adhesion: clinical features and management practice
Nagase, Y., Matsuzaki, S., Endo, M., Hara, T., Okada, A., Mimura, K., Hiramatsu, K., Kakigano, A., Nakatsuka, E., Miyake, T., et al. (2021) · BMC Surgery · doi:10.1186/s12893-020-01027-9 · Cited by 14
“In a retrospective study investigating 188 women with PP with prior CD has shown that ultrasound performed between 11 and 14 weeks’ gestation had a good diagnostic accuracy for detecting PAS [35].”
BackgroundAutomatic ultrasound assessment of placenta previa during the third trimester for rural areas
Saavedra, A. C., Arroyo, J., Tamayo, L., Egoavil, M., Ramos, B., & Castaneda, B. (2020) · 2020 IEEE International Ultrasonics Symposium (IUS) · doi:10.1109/ius46767.2020.9251764 · Cited by 12
“different research groups presented works on the identification of placenta previa in both urban and rural populations [9]–[11], the approaches attempting to automatize this task are scarce.”
Background
Metadata
- Authors
- Cali, G., Forlani, F., Foti, F., Minneci, G., Manzoli, L., Flacco, M. E., Buca, D., Liberati, M., Scambia, G., & D'Antonio, F.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2018-07-05
- Volume
- 52
- Issue
- 2
- Pages
- 258-264
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2793379248
- Cited by
- 44
- References
- 8
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.