Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 171

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Predictive accuracy of cerebroplacental ratio for adverse perinatal and neurodevelopmental outcomes in suspected fetal growth restriction: systematic review and meta‐analysis

Open access
Conde‐Agudelo, A., Villar, J., Kennedy, S. H., Papageorghiou, A. T. · 2018 · Ultrasound in Obstetrics & Gynecology

Abstract

Objective: The cerebroplacental ratio (CPR) has been proposed for the routine surveillance of pregnancies with suspected fetal growth restriction (FGR), but the predictive performance of this test is unclear. The aim of this study was to determine the accuracy of CPR for predicting adverse perinatal and neurodevelopmental outcomes in suspected FGR. Methods: PubMed, EMBASE, CINAHL and Lilacs were searched from inception to 31 July 2017 for cohort or cross‐sectional studies reporting on the accuracy of CPR for predicting adverse perinatal and/or neurodevelopmental outcomes in singleton pregnancies with FGR suspected antenatally based on sonographic parameters. Summary receiver–operating characteristics (ROC) curves, pooled sensitivities and specificities, and summary likelihood ratios (LRs) were generated. Results: Twenty‐two studies (including 4301 women) met the inclusion criteria. Summary ROC curves showed that the best predictive accuracy of CPR was for perinatal death and the worst was for neonatal acidosis, with areas under the summary ROC curves of 0.83 and 0.57, respectively. The predictive accuracy of CPR was moderate to high for perinatal death (pooled sensitivity and specificity of 93% and 76%, respectively, and summary positive and negative LRs of 3.9 and 0.09, respectively) and low for composite of adverse perinatal outcomes, Cesarean section for non‐reassuring fetal status, 5‐min Apgar score < 7, admission to the neonatal intensive care unit, neonatal acidosis and neonatal morbidity, with summary positive and negative LRs ranging from 1.1 to 2.5 and 0.3 to 0.9, respectively. An abnormal CPR result had moderate accuracy for predicting small‐for‐gestational age at birth (summary positive LR of 7.4). CPR had a higher predictive accuracy in pregnancies with suspected early‐onset FGR. No study provided data for assessing the predictive accuracy of CPR for adverse neurodevelopmental outcome. Conclusion: CPR appears to be useful in predicting perinatal death in pregnancies with suspected FGR. Nevertheless, before incorporating CPR into the routine clinical management of suspected FGR, randomized controlled trials should assess whether the use of CPR reduces perinatal death or other adverse perinatal outcomes. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.19117

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 171

Metadata

Authors
Conde‐Agudelo, A., Villar, J., Kennedy, S. H., & Papageorghiou, A. T.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2018-09-05
Volume
52
Issue
4
Pages
430-441
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2809682203
Cited by
171
References
9
FWCI
4.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.