CoChat

Prediction of pre‐eclampsia: review of reviews

Open access
Townsend, R., Khalil, A., Premakumar, Y., Allotey, J., Snell, K. I. E., Chan, C., Chappell, L. C., Hooper, R., Green, M., Mol, B. W., Thilaganathan, B., Thangaratinam, S., on behalf of the IPPIC Network · 2019 · Ultrasound in Obstetrics & Gynecology
Cited by 219

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Objective: Primary studies and systematic reviews provide estimates of varying accuracy for different factors in the prediction of pre‐eclampsia. The aim of this study was to review published systematic reviews to collate evidence on the ability of available tests to predict pre‐eclampsia, to identify high‐value avenues for future research and to minimize future research waste in this field. Methods: MEDLINE, EMBASE and The Cochrane Library including DARE (Database of Abstracts of Reviews of Effects) databases, from database inception to March 2017, and bibliographies of relevant articles were searched, without language restrictions, for systematic reviews and meta‐analyses on the prediction of pre‐eclampsia. The quality of the included reviews was assessed using the AMSTAR tool and a modified version of the QUIPS tool. We evaluated the comprehensiveness of search, sample size, tests and outcomes evaluated, data synthesis methods, predictive ability estimates, risk of bias related to the population studied, measurement of predictors and outcomes, study attrition and adjustment for confounding. Results: From 2444 citations identified, 126 reviews were included, reporting on over 90 predictors and 52 prediction models for pre‐eclampsia. Around a third (n = 37 (29.4%)) of all reviews investigated solely biochemical markers for predicting pre‐eclampsia, 31 (24.6%) investigated genetic associations with pre‐eclampsia, 46 (36.5%) reported on clinical characteristics, four (3.2%) evaluated only ultrasound markers and six (4.8%) studied a combination of tests; two (1.6%) additional reviews evaluated primary studies investigating any screening test for pre‐eclampsia. Reviews included between two and 265 primary studies, including up to 25 356 688 women in the largest review. Only approximately half (n = 67 (53.2%)) of the reviews assessed the quality of the included studies. There was a high risk of bias in many of the included reviews, particularly in relation to population representativeness and study attrition. Over 80% (n = 106 (84.1%)) summarized the findings using meta‐analysis. Thirty‐two (25.4%) studies lacked a formal statement on funding. The predictors with the best test performance were body mass index (BMI) > 35 kg/m 2, with a specificity of 92% (95% CI, 89–95%) and a sensitivity of 21% (95% CI, 12–31%); BMI > 25 kg/m 2, with a specificity of 73% (95% CI, 64–83%) and a sensitivity of 47% (95% CI, 33–61%); first‐trimester uterine artery pulsatility index or resistance index > 90 th centile (specificity 93% (95% CI, 90–96%) and sensitivity 26% (95% CI, 23–31%)); placental growth factor (specificity 89% (95% CI, 89–89%) and sensitivity 65% (95% CI, 63–67%)); and placental protein 13 (specificity 88% (95% CI, 87–89%) and sensitivity 37% (95% CI, 33–41%)). No single marker had a test performance suitable for routine clinical use. Models combining markers showed promise, but none had undergone external validation. Conclusions: This review of reviews calls into question the need for further aggregate meta‐analysis in this area given the large number of published reviews subject to the common limitations of primary predictive studies. Prospective, well‐designed studies of predictive markers, preferably randomized intervention studies, and combined through individual‐patient data meta‐analysis are needed to develop and validate new prediction models to facilitate the prediction of pre‐eclampsia and minimize further research waste in this field. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.20117

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

Metadata

Authors
Townsend, R., Khalil, A., Premakumar, Y., Allotey, J., Snell, K. I. E., Chan, C., Chappell, L. C., Hooper, R., Green, M., Mol, B. W., Thilaganathan, B., Thangaratinam, S., & on behalf of the IPPIC Network
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2019-07
Volume
54
Issue
1
Pages
16-27
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2892536996
Cited by
219
References
20
FWCI
9.41
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.