Development and validation of a machine‐learning model for prediction of shoulder dystocia
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objectives: To develop a machine‐learning (ML) model for prediction of shoulder dystocia (ShD) and to externally validate the model's predictive accuracy and potential clinical efficacy in optimizing the use of Cesarean delivery in the context of suspected macrosomia. Methods: We used electronic health records (EHR) from the Sheba Medical Center in Israel to develop the model (derivation cohort) and EHR from the University of California San Francisco Medical Center to validate the model's accuracy and clinical efficacy (validation cohort). Subsequent to application of inclusion and exclusion criteria, the derivation cohort included 686 singleton vaginal deliveries, of which 131 were complicated by ShD, and the validation cohort included 2584 deliveries, of which 31 were complicated by ShD. For each of these deliveries, we collected maternal and neonatal delivery outcomes coupled with maternal demographics, obstetric clinical data and sonographic fetal biometry. Biometric measurements and their derived estimated fetal weight were adjusted (aEFW) according to gestational age at delivery. A ML pipeline was utilized to develop the model. Results: In the derivation cohort, the ML model provided significantly better prediction than did the current clinical paradigm based on fetal weight and maternal diabetes: using nested cross‐validation, the area under the receiver‐operating‐characteristics curve (AUC) of the model was 0.793 ± 0.041, outperforming aEFW combined with diabetes (AUC = 0.745 ± 0.044, P = 1e−16). The following risk modifiers had a positive beta that was > 0.02, i.e. they increased the risk of ShD: aEFW (beta = 0.164), pregestational diabetes (beta = 0.047), prior ShD (beta = 0.04), female fetal sex (beta = 0.04) and adjusted abdominal circumference (beta = 0.03). The following risk modifiers had a negative beta that was < −0.02, i.e. they were protective of ShD: adjusted biparietal diameter (beta = −0.08) and maternal height (beta = −0.03). In the validation cohort, the model outperformed aEFW combined with diabetes (AUC = 0.866 vs 0.784, P = 0.00007). Additionally, in the validation cohort, among the subgroup of 273 women carrying a fetus with aEFW ≥ 4000 g, the aEFW had no predictive power (AUC = 0.548), and the model performed significantly better (0.775, P = 0.0002). A risk‐score threshold of 0.5 stratified 42.9% of deliveries to the high‐risk group, which included 90.9% of ShD cases and all cases accompanied by maternal or newborn complications. A more specific threshold of 0.7 stratified only 27.5% of the deliveries to the high‐risk group, which included 63.6% of ShD cases and all those accompanied by newborn complications. Conclusion: We developed a ML model for prediction of ShD and, in a different cohort, externally validated its performance. The model predicted ShD better than did estimated fetal weight either alone or combined with maternal diabetes, and was able to stratify the risk of ShD and neonatal injury in the context of suspected macrosomia. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682 · cited 1×
“For this reason, we adjusted all biometric parameters (BPD, HC, AC and FL), as well as the EFW, according to GA at delivery, by means of commonly used Hadlock equations 18–20 .”
MethodBig Data and Machine Learning in Health Care
Beam, A. L., & Kohane, I. S. (2018) · JAMA · doi:10.1001/jama.2017.18391 · Cited by 2,506 · cited 1×
“Machine-learning (ML) algorithms complement and extend classic statistical methods and can detect patterns from large, heterogeneous and complex data 16,17 .”
BackgroundStatistics versus machine learning
Bzdok, D., Altman, N., & Krzywinski, M. (2018) · Nature Methods · doi:10.1038/nmeth.4642 · Cited by 1,508 · cited 1×
“Machine-learning (ML) algorithms complement and extend classic statistical methods and can detect patterns from large, heterogeneous and complex data 16,17 .”
BackgroundIn utero analysis of fetal growth: a sonographic weight standard
Hadlock, F. P., Harrist, R. B., & Martinez-Poyer, J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887021 · Cited by 1,281
Cited by
Introduction to artificial intelligence in ultrasound imaging in obstetrics and gynecology
Drukker, L., Noble, J. A., & Papageorghiou, A. T. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22122 · Cited by 240
“…organ function 23,24 and breast lesions 25–27 , assess aneuploidy risk 28 , predict fetal lung maturity 29 , perinatal outcome 30 , shoulder dystocia 31 and brain damage 32 , estimate gestational age in late pregnancy 33 and classify standard fetal brain images as normal or abnormal 34 (Table 1).”
BackgroundUse of artificial intelligence in obstetrics: Not quite ready for prime time
Sarno, L., Neola, D., Carbone, L., Saccone, G., Carlea, A., Miceli, M., Iorio, G. G., Mappa, I., Rizzo, G., Girolamo, R. D., et al. (2023) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2022.100792 · Cited by 47
Machine learning and disease prediction in obstetrics
Arain, Z., Iliodromiti, S., Slabaugh, G., David, A. L., & Chowdhury, T. T. (2023) · Current Research in Physiology · doi:10.1016/j.crphys.2023.100099 · Cited by 40
“In intrapartum management, studies lacked external validation or quality assessment (Tan et al., 2021; Ghi et al., 2022; Tsur et al., 2020; Venkatesh et al., 2020; Chill et al., 2021) but are a first step in developing clinical decision assist tools to improve safety standards.”
BackgroundGhi, T., Conversano, F., Ramirez Zegarra, R., Pisani, P., Dall'Asta, A., Lanzone, A., Lau, W., Vimercati, A., Iliescu, D. G., Mappa, I., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23739 · Cited by 32
Metadata
- Authors
- Tsur, A., Batsry, L., Toussia‐Cohen, S., Rosenstein, M. G., Barak, O., Brezinov, Y., Yoeli‐Ullman, R., Sivan, E., Sirota, M., Druzin, M. L., Stevenson, D. K., Blumenfeld, Y. J., & Aran, D.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2020-10
- Volume
- 56
- Issue
- 4
- Pages
- 588-596
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2978564376
- Cited by
- 52
- References
- 4
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and validation of a machine‐learning model for prediction of shoulder dystocia. https://app.cochat.ai/papers/10.1002/uog.21878
- The paper
- Tsur, A., Batsry, L., Toussia‐Cohen, S., Rosenstein, M. G., Barak, O., Brezinov, Y., Yoeli‐Ullman, R., Sivan, E., Sirota, M., Druzin, M. L., Stevenson, D. K., Blumenfeld, Y. J., & Aran, D. (2020). Development and validation of a machine‐learning model for prediction of shoulder dystocia. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.21878
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.