The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
A novel approach to first‐trimester screening for early pre‐eclampsia combining serum PP‐13 and Doppler ultrasound
Open accessAbstract
Objective: To investigate the value of maternal serum placental protein 13 (PP‐13) measurement and uterine artery Doppler during first‐trimester screening in the prediction of early pre‐eclampsia. Methods: This was a nested case‐control prospective study of pregnancies at 11 + 0 to 13 + 6 weeks of gestation. The pulsatility index (PI) of blood flow in the uterine arteries and the maternal serum concentration of PP‐13 were measured in 10 women who went on to develop pre‐eclampsia that necessitated delivery before 34 weeks, and in 423 unaffected women. Results were expressed as multiples of the gestation‐specific median in controls (MoM). A logistic regression model was used to predict detection and false‐positive rates. Results: In the cases that developed pre‐eclampsia requiring delivery before 34 weeks, compared with the unaffected pregnancies, the median uterine artery PI was higher (1.43 MoM) and the median serum PP‐13 level was lower (0.07 MoM; P < 0.001, Wilcoxon rank sum test for both). Modeling predicted that for a 90% detection rate of pre‐eclampsia requiring delivery before 34 weeks, the false‐positive rate of screening by PP‐13 was 12%, by uterine artery PI was 31% and by a combination of the two methods was 9%. A policy of contingency screening, whereby all women are screened by maternal serum PP‐13 and only the 14% at highest risk are then screened by Doppler, achieved a detection rate of 90% with an overall false‐positive rate of 6%. Conclusion: Effective screening for pre‐eclampsia requiring delivery before 34 weeks can potentially be provided by assessment of a combination of maternal serum PP‐13 and uterine artery Doppler in the first trimester of pregnancy. Copyright © 2005 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brown, M. A., Lindheimer, M. D., Swiet, M. D., Assche, A. V., & Moutquin, J.-M. (2001) · Hypertension in Pregnancy · doi:10.1081/prg-100104165 · Cited by 1,894
KHONG, T. Y., DE WOLF, F., ROBERTSON, W. B., & BROSENS, I. (1986) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1986.tb07830.x · Cited by 1,591
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Placental bed spiral arteries in the hypertensive disorders of pregnancy
PIJNENBORG, R., ANTHONY, J., DAVEY, D. A., REES, A., TILTMAN, A., VERCRUYSSE, L., & VAN ASSCHE, A. (1991) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1991.tb13450.x · Cited by 673
Prevention of Preeclampsia with Low-Dose Aspirin in Healthy, Nulliparous Pregnant Women
Sibai, B. M., Caritis, S. N., Thom, E., Klebanoff, M., McNellis, D., Rocco, L., Paul, R. H., Romero, R., Witter, F., Rosen, M., et al. (1993) · New England Journal of Medicine · doi:10.1056/nejm199310213291701 · Cited by 558
Martin, A. M., Bindra, R., Curcio, P., Cicero, S., & Nicolaides, K. H. (2001) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00594.x · Cited by 451
Self-citationPrevention of Preeclampsia With Low-Dose Aspirin in Healthy, Nulliparous Pregnant Women
Sibai, B. M., Caritis, S. N., Thom, E., Klebanoff, M., McNellis, D., Rocco, L., Paul, R. H., Romero, R., Witter, F., Rosen, M., et al. (1994) · Obstetrical & Gynecological Survey · doi:10.1097/00006254-199404000-00002 · Cited by 249
Second-trimester uterine artery Doppler screening in unselected populations: a review
Papageorghiou, A. T., Yu, C. K. H., Cicero, S., Bower, S., & Nicolaides, K. H. (2002) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/713605620 · Cited by 243
Self-citationVainio, M. (2002) · BJOG: An International Journal of Obstetrics and Gynaecology · doi:10.1016/s1470-0328(02)01046-7 · Cited by 176
Model‐based screening by risk with application to down's syndrome
Royston, P., & Thompson, S. G. (1992) · Statistics in Medicine · doi:10.1002/sim.4780110211 · Cited by 173
Yu, C. K. H., Papageorghiou, A. T., Parra, M., Palma Dias, R., Nicolaides, K. H., & The Fetal Medicine Foundation Second Trimester Screening Group (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.218 · Cited by 170
Self-citationFunctional analyses of placental protein 13/galectin‐13
Than, N. G., Pick, E., Bellyei, S., Szigeti, A., Burger, O., Berente, Z., Janaky, T., Boronkai, A., Kliman, H., Meiri, H., et al. (2004) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.2004.04004.x · Cited by 165
Self-citationBurger, O., Pick, E., Zwickel, J., Klayman, M., Meiri, H., Reich‐Slotky, R., Mandel, S., Rabinovitch, L., Paltieli, Y., Admon, A., et al. (2004) · Placenta · doi:10.1016/j.placenta.2003.12.009 · Cited by 139
Self-citationWright, D., Bradbury, I., BENN, P. A., Cuckle, H., & Ritchie, K. (2004) · Prenatal Diagnosis · doi:10.1002/pd.974 · Cited by 118
Self-citationA small randomised trial of low-dose aspirin in women at high risk of pre-eclampsia
Chiaffarino, F., Parazzini, F., Paladini, D., Acaia, B., Ossola, W., Marozio, L., Facchinetti, F., & Giudice, A. D. (2003) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(03)00269-0 · Cited by 60
Christiansen, M., & Larsen, S. O. (2002) · Prenatal Diagnosis · doi:10.1002/pd.336 · Cited by 46
Cited by
Placental Origins of Preeclampsia: Challenging the Current Hypothesis
Huppertz, B. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.107607 · Cited by 893
Uterine artery Doppler at 11 + 0 to 13 + 6 weeks in the prediction of pre‐eclampsia
Plasencia, W., Maiz, N., Bonino, S., Kaihura, C., & Nicolaides, K. H. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5157 · Cited by 425
Self-citationOgge, G., Chaiworapongsa, T., Romero, R., Hussein, Y., Kusanovic, J. P., Yeo, L., Kim, C. J., & Hassan, S. S. (2011) · Journal of Perinatal Medicine · doi:10.1515/jpm.2011.098 · Cited by 299
Potential markers of preeclampsia – a review
Grill, S., Rusterholz, C., Zanetti-Dällenbach, R., Tercanli, S., Holzgreve, W., Hahn, S., & Lapaire, O. (2009) · Reproductive Biology and Endocrinology · doi:10.1186/1477-7827-7-70 · Cited by 293
Vascular biology of preeclampsia
Myatt, L., & Webster, R. P. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2008.03259.x · Cited by 292
Metadata
- Authors
- Nicolaides, K. H., Bindra, R., Turan, O. M., Chefetz, I., Sammar, M., Meiri, H., Tal, J., & Cuckle, H. S.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2005-12-22
- Volume
- 27
- Issue
- 1
- Pages
- 13-17
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2155693947
- Cited by
- 268
- References
- 16
- FWCI
- 17.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.