The DOI matches its Crossref record.
French fetal biometry: reference equations and comparison with other charts
Open accessAbstract
Objectives: To construct new reference charts and equations for fetal biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), using a large sample of fetuses examined at 15–40 weeks in France, and to compare them with previous references. Methods: The study data were obtained over a continuous 1‐year period from a population of pregnant women undergoing ultrasound examination. Excluded were those with a known abnormal karyotype or congenital malformation, multiple pregnancies, and those with no first‐trimester dating based on crown–rump length. No fetuses were excluded on the basis of abnormal biometry or birth weight. For each measurement, separate regression models were fitted to estimate both the mean and the SD at each gestational age. Results: Full biometric measurements were obtained for 19 647 fetuses. New charts and reference equations are reported for BPD, HC, AC and FL. Prediction intervals for the new reference charts were similar to those of previous ones, whereas there were some differences in predicted centiles. Conclusion: We present new French reference charts and equations for fetal biometry. They can be used easily to compute centiles and Z‐scores to control the quality of biometric assessments and to evaluate their performance relative to other references. Copyright © 2006 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Verburg, B. O., Steegers, E. A. P., De Ridder, M., Snijders, R. J. M., Smith, E., Hofman, A., Moll, H. A., Jaddoe, V. W. V., & Witteman, J. C. M. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5225 · Cited by 506
McCowan, L. M., Figueras, F., & Anderson, N. H. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.12.004 · Cited by 451
Defining normal and abnormal fetal growth: promises and challenges
Zhang, J., Merialdi, M., Platt, L. D., & Kramer, M. S. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.10.889 · Cited by 264
Ultrasound Evidence of Early Fetal Growth Restriction after Maternal Malaria Infection
Rijken, M. J., Papageorghiou, A. T., Thiptharakun, S., Kiricharoen, S., Dwell, S. L. M., Wiladphaingern, J., Pimanpanarak, M., Kennedy, S. H., Nosten, F., & McGready, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031411 · Cited by 80
Stirnemann, J. J., Fries, N., Bessis, R., Fontanges, M., Mangione, R., & Salomon, L. J. (2017) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.17223 · Cited by 37
Self-citation
Metadata
- Authors
- Salomon, L. J., Duyme, M., Crequat, J., Brodaty, G., Talmant, C., Fries, N., & Althuser, M.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2006-03-28
- Volume
- 28
- Issue
- 2
- Pages
- 193-198
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2027822008
- Cited by
- 177
- References
- 0
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: French fetal biometry: reference equations and comparison with other charts. https://app.cochat.ai/papers/10.1002/uog.2733
- The paper
- Salomon, L. J., Duyme, M., Crequat, J., Brodaty, G., Talmant, C., Fries, N., & Althuser, M. (2006). French fetal biometry: reference equations and comparison with other charts. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.2733
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.