CoChat

Middle cerebral artery peak systolic velocity: a new Doppler parameter in the assessment of growth‐restricted fetuses

Open access
Mari, G., Hanif, F., Kruger, M., Cosmi, E., Santolaya‐Forgas, J., Treadwell, M. C. · 2007 · Ultrasound in Obstetrics & Gynecology
Cited by 152

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: The aims of this study were to determine if there is a relationship between middle cerebral artery (MCA) peak systolic velocity (PSV) and perinatal mortality in preterm intrauterine growth‐restricted (IUGR) fetuses, to compare the performance of MCA pulsatility index (PI), MCA‐PSV and umbilical artery (UA) absent/reversed end‐diastolic velocity (ARED) in predicting perinatal mortality, to determine the longitudinal changes that occur in MCA‐PI and MCA‐PSV in these fetuses, and to test the hypothesis that MCA‐PSV can provide additional information on the prognosis of hypoxemic IUGR fetuses. Methods: This was a retrospective cross‐sectional study of 30 IUGR fetuses (estimated fetal weight < 3 rd percentile; UA‐PI > 95% CI) in which the last MCA‐PI, MCA‐PSV and UA values were obtained within 8 days before delivery or fetal demise. Among the 30 fetuses, there were 10 in which at least three consecutive measurements were performed before delivery and these were used for a longitudinal study. MCA‐PSV and MCA‐PI values were plotted against normal reference ranges and were considered abnormal when they were above the MCA‐PSV or below the MCA‐PI reference ranges. Results: Gestational age at delivery ranged between 23 + 1 and 32 + 5 (median, 27 + 6) gestational weeks. Birth weight ranged from 282 to 1440 (median, 540) g. There were 11 perinatal deaths. Forward stepwise logistic regression indicated that MCA‐PSV was the best parameter in the prediction of perinatal mortality (odds ratio, 14; 95% CI, 1.4–130; P < 0.05) (Nagerlke R2 = 31). In the 10 fetuses studied longitudinally, an abnormal MCA‐PI preceded the appearance of an abnormal MCA‐PSV. In these fetuses, the MCA‐PSV consistently showed an initial increase in velocity; before demise or the appearance of a non‐reassuring test in seven fetuses, there was a decrease in blood velocity. The MCA‐PI presented an inconsistent pattern. Conclusions: In IUGR fetuses, the trends of the MCA‐PI and MCA‐PSV provide more clinical information than does one single measurement. A high MCA‐PSV predicts perinatal mortality better than does a low MCA‐PI. We propose that MCA‐PSV might be valuable in the clinical assessment of IUGR fetuses that have abnormal UA Doppler. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.3953

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Mari, G., Hanif, F., Kruger, M., Cosmi, E., Santolaya‐Forgas, J., & Treadwell, M. C.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2007-02-23
Volume
29
Issue
3
Pages
310-316
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2143648300
Cited by
152
References
2
FWCI
10.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.