Is three‐dimensional power Doppler ultrasound useful in the assessment of placental perfusion in normal and growth‐restricted pregnancies?
The DOI matches its Crossref record.
Abstract
Objectives: To investigate three‐dimensional (3D) power Doppler ultrasound indices in the assessment of placental perfusion and their relationship to gestational age (GA), placental position and umbilical artery Doppler flow velocity waveform (FVW) patterns in normal and intrauterine growth‐restricted (IUGR) pregnancies. Methods: Forty‐five pregnant women at 23–37 weeks' gestation were studied, of whom 30 had IUGR and 15 were controls. Nine of the IUGR group had normal umbilical FVWs (NED), nine had abnormal patterns but positive end‐diastolic velocities (PED) and 12 had absent or reversed end‐diastolic velocities (AED). Placental position was assessed as being posterior, anterior or lateral. 3D power Doppler indices related to placental perfusion (vascularization index (VI), vascularization flow index (VFI) and flow index (FI)) were obtained from five different sampling sites in each placenta. Results: VI, VFI and FI were not significantly dependent on GA or placental position. VI and VFI were significantly lower in PED and AED cases compared with controls, while FI was reduced in the AED group only. VI and VFI showed high variability between different sampling sites within each placenta, while the variability of FI was much lower. Conclusions: 3D power Doppler sonography can provide new insights into placental pathophysiology. FI, which identifies the most severe cases of placental impairment, appears to be the most reliable index because of its low intraplacental variability. Further studies are needed to verify its accuracy when applied in clinical practice as a substitute for or an adjunct to umbilical artery Doppler studies. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ogge, G., Chaiworapongsa, T., Romero, R., Hussein, Y., Kusanovic, J. P., Yeo, L., Kim, C. J., & Hassan, S. S. (2011) · Journal of Perinatal Medicine · doi:10.1515/jpm.2011.098 · Cited by 299
Hafner, E., Metzenbauer, M., Stümpflen, I., Waldhör, T., & Philipp, K. (2010) · Placenta · doi:10.1016/j.placenta.2010.06.011 · Cited by 67
Jones, N. W., Raine-Fenning, N. J., Mousa, H. A., Bradley, E., & Bugg, G. J. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.11.018 · Cited by 32
Automatic placental maturity grading via hybrid learning
Lei, B., Tan, E.-L., Chen, S., Li, W., Ni, D., Yao, Y., & Wang, T. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.033 · Cited by 5
Hybrid descriptor for placental maturity grading
Lei, B., Jiang, F., Zhou, F., Ni, D., Yao, Y., Chen, S., & Wang, T. (2020) · Multimedia Tools and Applications · doi:10.1007/s11042-019-08489-x · Cited by 3
Metadata
- Authors
- Guiot, C., Gaglioti, P., Oberto, M., Piccoli, E., Rosato, R., & Todros, T.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2008-02
- Volume
- 31
- Issue
- 2
- Pages
- 171-176
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W1966130772
- Cited by
- 149
- References
- 0
- FWCI
- 17.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is three‐dimensional power Doppler ultrasound useful in the assessment of placental perfusion in normal and growth‐restricted pregnancies? https://app.cochat.ai/papers/10.1002/uog.5212
- The paper
- Guiot, C., Gaglioti, P., Oberto, M., Piccoli, E., Rosato, R., & Todros, T. (2008). Is three‐dimensional power Doppler ultrasound useful in the assessment of placental perfusion in normal and growth‐restricted pregnancies? Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.5212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.