The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Uterine artery Doppler at 11 + 0 to 13 + 6 weeks and 21 + 0 to 24 + 6 weeks in the prediction of pre‐eclampsia
Open accessAbstract
Objective: To evaluate the performance of screening for pre‐eclampsia by uterine artery pulsatility index (PI) at 11 + 0 to 13 + 6 weeks' gestation and the change in uterine artery PI between 11 + 0 to 13 + 6 and 21 + 0 to 24 + 6 weeks. Methods: In 3107 singleton pregnancies attending for routine care at 11 + 0 to 13 + 6 and 21 + 0 to 24 + 6 weeks' gestation we recorded maternal characteristics and medical and obstetric history, and measured uterine artery PI. The distributions of uterine artery PI were made Gaussian after logarithmic transformation and the log of the ratio of uterine artery PI at 21 + 0 to 24 + 6 weeks to that at 11 + 0 to 13 + 6 weeks was calculated. Multiple regression analysis was used to determine which of the maternal variables and Doppler findings were significant predictors of early and late pre‐eclampsia. The performance of screening was described by receiver–operating characteristics curves. Results: Pre‐eclampsia developed in 93 (3.0%) pregnancies, including 22 (0.7%) in which delivery was before 34 weeks (early pre‐eclampsia) and 71 (2.3%) with delivery at 34 weeks or more (late pre‐eclampsia). Seventy‐three (2.3%) women developed gestational hypertension, 346 (11.1%) delivered small‐for‐gestational‐age (SGA) babies with no hypertensive disorders and 2595 (83.5%) were unaffected by pre‐eclampsia, gestational hypertension or SGA. Multiple regression analysis demonstrated that maternal variables, uterine artery PI at 11 + 0 to 13 + 6 weeks and the change in uterine artery PI between 11 + 0 to 13 + 6 and 21 + 0 to 24 + 6 weeks' gestation provided significant independent contributions to the prediction of pre‐eclampsia. For a false positive rate of 5% the predicted detection rates of early and late pre‐eclampsia were 90.9 and 31.0%, respectively. The same performance of screening was achieved by reserving second‐trimester testing for only the 20% of women at the highest risk after first‐trimester screening. Conclusion: The decrease in uterine artery PI between 11 + 0 to 13 + 6 and 21 + 0 to 24 + 6 weeks is steeper in pregnancies with a normal outcome than in those developing pre‐eclampsia. Effective screening for pre‐eclampsia can be achieved by the Doppler measurement of uterine artery PI at 11 + 0 to 13 + 6 weeks and the change in PI between 11 + 0 to 13 + 6 and 21 + 0 to 24 + 6 weeks. Copyright © 2008 ISUOG. Published by John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
KHONG, T. Y., DE WOLF, F., ROBERTSON, W. B., & BROSENS, I. (1986) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1986.tb07830.x · Cited by 1,591
Irgens, H. U., Roberts, J. M., Reisæter, L., Irgens, L. M., & Lie, R. T. (2001) · BMJ · doi:10.1136/bmj.323.7323.1213 · Cited by 1,040
Uterine artery Doppler at 11 + 0 to 13 + 6 weeks in the prediction of pre‐eclampsia
Plasencia, W., Maiz, N., Bonino, S., Kaihura, C., & Nicolaides, K. H. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5157 · Cited by 425
Self-citation
Cited by
Bartsch, E., Medcalf, K. E., Park, A. L., & Ray, J. G. (2016) · BMJ · doi:10.1136/bmj.i1753 · Cited by 996
First trimester preeclampsia screening and prediction
Chaemsaithong, P., Sahota, D. S., & Poon, L. C. (2022) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.07.020 · Cited by 363
Self-citationKusanovic, J. P., Romero, R., Chaiworapongsa, T., Erez, O., Mittal, P., Vaisbuch, E., Mazaki-Tovi, S., Gotsch, F., Edwin, S. S., Gomez, R., et al. (2009) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767050902994754 · Cited by 275
Pre-eclampsia part 2: prediction, prevention and management
Chaiworapongsa, T., Chaemsaithong, P., Korzeniewski, S. J., Yeo, L., & Romero, R. (2014) · Nature Reviews Nephrology · doi:10.1038/nrneph.2014.103 · Cited by 132
Caradeux, J., Martinez-Portilla, R. J., Peguero, A., Sotiriadis, A., & Figueras, F. (2019) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.09.043 · Cited by 122
Metadata
- Authors
- Plasencia, W., Maiz, N., Poon, L., Yu, C., & Nicolaides, K. H.
- Venue
- Ultrasound in Obstetrics & Gynecology
- Publisher
- Wiley
- Published
- 2008-07-15
- Volume
- 32
- Issue
- 2
- Pages
- 138-146
- ISSN
- 0960-7692 (ISSN-L)
- 1469-0705
- OpenAlex
- W2132836147
- Cited by
- 190
- References
- 3
- FWCI
- 12.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uterine artery Doppler at 11 + 0 to 13 + 6 weeks and 21 + 0 to 24 + 6 weeks in the prediction of pre‐eclampsia. https://app.cochat.ai/papers/10.1002/uog.5402
- The paper
- Plasencia, W., Maiz, N., Poon, L., Yu, C., & Nicolaides, K. H. (2008). Uterine artery Doppler at 11 + 0 to 13 + 6 weeks and 21 + 0 to 24 + 6 weeks in the prediction of pre‐eclampsia. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.5402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.