CoChat

From nuchal translucency to intracranial translucency: towards the early detection of spina bifida

Chaoui, R., Nicolaides, K. H. · 2010 · Ultrasound in Obstetrics & Gynecology
Cited by 136

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

It is now clear that the vast majority of major fetal abnormalities can be diagnosed prenatally by ultrasound, that most of these abnormalities can be detected in the first trimester of pregnancy and that women want first-trimester rather than later diagnosis. It is also clear that effective diagnosis of fetal abnormalities often necessitates the identification of easily recognizable markers which direct the attention of the sonographer to the specific abnormality. Good examples of such markers are the scalloping of the frontal bones (the 'lemon' sign) and caudal displacement of the cerebellum (the 'banana' sign), observed in the second trimester in most fetuses with open spina bifida, and increased nuchal translucency thickness (NT) which identifies in the first trimester the majority of fetuses with major aneuploidies, lethal skeletal dysplasias and a high proportion of major cardiac defects. It is now widely accepted that increased NT at 11–13 weeks is the single most effective marker of trisomy 21 and all other major aneuploidies. First-trimester screening by a combination of maternal age, fetal NT, nasal bone, Doppler assessment of blood flow in the ductus venosus and across the tricuspid valve together with maternal serum free β-hCG and PAPP-A can identify more than 95% of all major aneuploidies for a screen-positive rate of less than 3%. A major remaining challenge in first-trimester ultrasonography has been the diagnosis of open spina bifida. This challenge, however, may now have been resolved by the realization that open spina bifida can be suspected by an easily detectable marker within the brain in the same mid-sagittal plane of the fetal face as for measurement of NT and assessment of the nasal bone. In normal fetuses the fourth cerebral ventricle presents as an intracranial translucency (IT) parallel to the NT, while in fetuses with open spina bifida there may be absence of the IT1. The two lines that define the IT are the posterior border of the brain stem anteriorly and the choroid plexus of the fourth ventricle posteriorly (Figure 1). Its measurement is similar to that of NT. The exact mid-sagittal plane of the fetal face should be obtained and the image should be magnified so that only the fetal head and upper thorax are included. The exact mid-sagittal plane of the fetal face is defined by the echogenic tip of the nose and rectangular shape of the palate anteriorly, the translucent thalamus in the center and the nuchal membrane posteriorly. Rotation of the head by about 10° away from the midline results in non-visibility of the tip of the nose and the appearance of the maxillary bone as an echogenic structure between the nasal bone above and the anterior part of the palate below. With further rotation, by about 15° from the midline, the nasal bone disappears and there is enlargement of the maxillary bone and coalescence with the palate. Exact mid-sagittal plane of the fetal face at 13 weeks (crown–rump length, 69 mm) showing the nasal bone (NB), nuchal translucency (NT), thalamus, midbrain (MB), brain stem (BS), cisterna magna (CM) and fourth ventricle. The fourth ventricle appears as an intracranial translucent (IT) area between two echogenic borders, the posterior border of the brain stem anteriorly and the choroid plexus of the fourth ventricle posteriorly. Measurement of the IT is achieved by placing the calipers on the anterior and posterior echogenic borders of the fourth ventricle. At 11–13 weeks the brain stem appears hypoechogenic (dark gray) whereas the IT is anechoic (black) (Figure 1). Posterior to the IT is the future cisterna magna. In the mid-sagittal plane the IT has a slightly curved appearance and the widest anteroposterior diameter is in the middle part of the fourth ventricle. In measuring IT, as for NT, we recommend selecting the translucency with the widest diameter and placing the calipers on the anterior and posterior echogenic borders. The exact mid-sagittal plane is ideal for measuring IT as it is for measuring NT and assessing the nasal bone. In this plane we can identify the fluid within the third ventricle between the right and left thalami and the aqueduct of Sylvius between the cerebral peduncles, although the thalami and peduncles themselves are not visible. The intracranial structures, including the thalamus, midbrain, brain stem, fourth ventricle and cisterna magna, can be identified easily in a slightly deviated parasagittal plane. Indeed, as shown in transverse view in Figure 2, the fourth ventricle remains wide on either side of the midline, therefore the effect of measuring the IT in planes that are slightly deviated from the exact mid-sagittal one should be minimal. (a) Parasagittal plane of the fetal face at 13 weeks, with visible choroid plexus (CP). (b) The transverse view of the head at the level of the fourth ventricle obtained transvaginally demonstrates that mild deviations in insonation from the midline (solid line) have minimal effect on the

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/uog.7552

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 136

Metadata

Authors
Chaoui, R., & Nicolaides, K. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
2010-01-25
Volume
35
Issue
2
Pages
133-138
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2151050648
Cited by
136
References
3
FWCI
11.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.